OM-185 648 Page 16

3-6. Remote 14 Receptacle Information

Socket* Socket Information
24 VOLTS AC A24 volts ac. Protected by circuit breaker CB2.
24 VOLTS AC
BContact closure to A completes 24 volts ac con-
tactor control circuit.
AJ
BKI115 VOLTS AC I115 volts ac. Protected by circuit breaker CB1.
CLNH
DMG
115 VOLTS AC
JContact closure to I completes 115 volts ac con-
tactor control circuit.
EF
COutput to remote control; +10 volts dc in MIG
mode.
DRemote control circuit common.
REMOTE
OUTPUT
CONTROL E0 to +10 volts dc input command signal from re-
mote control.
MMode select.
NRemote inductance control.

A/V

AMPERAGE
FCurrent feedback; +1 volt dc per 100 amperes.
Ref. ST-801 718 AMPERAGE
VOLTAGE HVoltage feedback; +1 volt dc per 10 arc volts.
GCircuit c o mm o n f o r 2 4 an d 115 volts ac circuits.
GND K Chassis common.
*The remaining sockets are not used.