OM-185 648 Page 17
3-7. 115 Volts AC Duplex Receptacle
Ref. ST-801 524-A
1 115 V 7 A AC Receptacle
Power is shared between duplex
receptacle and Remote 14 recep-
tacle (see Section 3-6).
2 Circuit Breaker CB1
3 Circuit Breaker CB2
CB1 protects 115 volts ac portion of
duplex receptacle and Remote 14
receptacle from overload.
CB2 protects 24 volts ac portion of
Remote 14 receptacle from
overload.
Press button to reset breaker.
2 3
1
3-8. Electrical Service Guide
Input Voltage 400
Input Amperes At Rated Output 31
Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes 45
Min Input Conductor Size in AWG/Kcmil 10
Max Recommended Input Conductor Length In Feet (Meters) 264 (80)
Min Grounding Conductor Size in AWG/Kcmil 10
Reference: 1993 National Electrical Code (NEC). S-0092J