OM-495 Page 32 Return To Table Of Contents

5-12. Connecting To Remote Amperage Adjust Receptacle RC13 On CC Models

Ref. 154 862-A / 048 720-K / 802 311
1 Remote Amperage Adjust
Receptacle RC13
Connect optional remote control to
RC13 (see Section 6-3).
1

5-13. Connecting To Remote 14 Receptacle RC14 On CC/CV Models

Socket* Socket Information
24 VOLTS AC
A24 volts ac. Protected by circuit
breaker CB5.
24 VOLTS AC
BContact closure to A completes
24 volt ac contactor control
circuit.
COutput to remote control:+10
volts dc in MIG or Stick mode;
0 to +10 volts dc in TIG mode.
New! LDR-14 long
distance remote REMOTE
OU
TP
U
T
DRemote control circuit common.
distance remote
(includes 120 V
receptacle)
OUTPUT
CONTROL EDC input command signal: 0 to
+10 volts from min. to max. of
remote control with Voltage/
Amperage Adjust control at
max.
OR 115 VOLTS AC
I115 volts, 10 amperes, 60 Hz
ac. Protected by circuit breaker
CB6.
JContact closure to I completes
115 volt ac contactor control
circuit.
802 311 GND KChassis common.
NEUTRAL GCircuit common for 24 and 115
volt ac circuit.
*The remaining sockets are not used.