SECTION 9 MAINTENANCE (DEUTZ F4L2011POWERED UNITS)

The oil/filter maintenance intervals are different for the Deutz F4L2011 and F3L912 engines

(see maintenance schedules following).

Note

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an

extended period.

Note

9-1. Routine Maintenance (Deutz F4L2011-Powered Units)

Recycle
engine
fluids.
Stop engine before maintaining.
See Engine Manual and Maintenance Label for
important start-up, service, and storage informa-
tion. Service engine more frequently if used in se-
vere conditions.
* To be done by Factory Authorized Service Agent.

Every 8 h

Wipe Up
Spills.
Check Fluid
Levels. See
Section 5-9.
Drain Water
From Fuel
System. See
Section 9-6.
FUEL
WATER

Every 50 h

Clean Air Filter.
See Section 9-3.
Clean And
Tighten Weld
Terminals.

Every 100 h

Clean
Cooling
System.
Clean And
Tighten
Battery
Connections.
Check air cleaner
hoses for cracks
and loose clamps.

Every 250 h

Replace
Unreadable
Labels.
1/2 in.
(13 mm) Check
Belt
Tension.
Check And
Clean Spark
Arrestor. See
Section 9-4.

Every 500 h

Repair Or
Replace
Cracked
Cables.