SECTION 7 − SETTING SEQUENCE PARAMETERS

7-1. Sequence Parameters In A Program

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence

 

Parameters

 

 

 

 

 

 

 

 

 

 

 

 

Volts

IPM

 

Seconds

 

 

 

 

 

 

 

 

1.

Preflow

 

 

 

0-9.9

 

 

 

 

 

 

 

 

2.

Run-In

 

X

 

 

 

 

 

 

 

 

 

 

3.

Start

X

X

 

0.00-5.00

 

 

 

 

 

 

 

 

4.

Weld

X

X

 

0-100.0

 

 

 

 

 

 

 

 

5.

Crater

X

X

 

0-5.00

 

 

 

 

 

 

 

 

6.

Burnback

X

 

 

0-0.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7. Postflow

 

 

 

0-9.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = Setting available.

 

 

 

 

.For more information on

Sequence Push Button see Section 6-11.

If time is set to zero in Weld sequence, welding continues until gun trigger is released.

If time is set to zero in any timed sequence except Weld, the sequence is skipped.

 

 

 

 

Weld Time

 

 

 

 

 

 

Crater

Burnback

 

 

 

 

Time

Time

 

 

 

 

 

Preflow

Start

 

Postflow

 

Time

Time

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

Time

 

Run-In Start

Weld

Burnback

 

Preflow

Crater

Postflow

Sequence

Trigger

 

 

 

Trigger

 

End

 

 

 

 

 

Pressed

 

 

 

Released

 

 

SECTION 8 − SETTING DUAL SCHEDULE PARAMETERS

8-1. Optional Dual Schedule Switch Diagrams

 

1

 

2

1 DSS-9

1

 

DSS-8 1

2

2

TR

2

 

 

 

 

 

 

3

 

 

 

B

A

3

A

 

 

 

 

 

 

 

4

B

4

 

 

1Maint 2P (Maintained-Contact 2-Pole Switch)

2Maint 1P (Maintained-Contact 1-Pole Switch)

.Will not function with trigger

hold and dual schedule. A DSS-9 is recommended for this application.