5-9. Power Source Selection Menu

Non-CE Model Shown

1

Program

Volts

Time (sec)

 

 

Wire Speed

Amps

Start

 

 

2

 

 

 

Crater

 

 

Trigger Hold

Pre/Postflow

 

 

Dual Schedule

SequenceAdjustSetup

* * Power Source

Upper Display

Lower Display

Voltage Range

 

 

 

 

 

Deltaweld 452

dELT

452

Vmin =10

Vmax =38

Deltaweld 302

dELT

302

Vmin =10

Vmax =32

Deltaweld 652

dELT

652

Vmin =10

Vmax =44

Dimension 302

dIM

302

Vmin =10

Vmax =32

Dimension 452

dIM

452

Vmin =10

Vmax =38

Dimension 652

dIM

652

Vmin =10

Vmax =65

 

 

 

 

 

Dimension 1000

dIM

1000

Vmin =10

Vmax =60

 

 

 

 

 

XMT 304

XMT

304

Vmin =10

Vmax =35

 

 

 

 

 

XMT 456

XMT

456

Vmin =10

Vmax =38

 

 

 

 

 

Invision 354MP

I354

MP

Vmin =10

Vmax =35

 

 

 

 

 

Invision 456MP

I456

MP

Vmin =10

Vmax =38

 

 

 

 

 

Invision 456P

I456

P

Vmin =10

Vmax =38

 

 

 

 

 

PHOENIX 456

PHX

456

Vmin =10

Vmax =38

 

 

 

 

 

SUMMITARC 1000

SUM

1000

Vmin =25

Vmax =44

 

 

 

 

 

 

 

 

 

 

**For any power sources not listed, pick a matching voltage range, or see Sec 5-12 to set Vmin and Vmax.

1Upper Display

2Lower Display

.When the feeder is turned on,

the Power Source Selection Menu allows the operator to se- lect a default power source. Selecting a default power source, automatically sets the correct Vmin and Vmax set- tings for adjusting the output voltage of the power source.

First Time Feeder Is Turned On

The feeder automatically goes into the Power Source Selection Menu. The feeder displays “dELT” on the Upper Display and “452” on the Lower Display, meaning that a Del- taweld 452 is the default power source, and has a voltage range of 10V as Vmin and 38V as Vmax.

At power up, the operator has three seconds to select a default power source from the list shown on the display. Operator may scroll through the list of power sources by using the Adjust control. After se- lecting a power source the operator has three seconds to change to a different power source or begin welding. After making a power source selection, the operator may press the Program Button to avoid having to wait the three seconds. When turning off the feeder, the de- fault power source will be retained.

If voltage settings have already been set with the Vmin and Vmax in the Auxiliary Menu, selecting a de- fault power source with the Power Source Selection Menu overrides the Vmin and Vmax voltage set- tings.

Next Time Feeder Is Turned On

The feeder will display the last se- lected default power source. The operator has three seconds to se- lect another power source, or press the Program Button to exit the Pow- er Source Selection Menu.

Disabling The Power Source Selection Menu

Once the default power source has been selected the Power Source Selection Menu may be disabled using the Auxiliary Menus. See Section 6-12.

OM-1500-7 Page 19