5-5. Troubleshooting

5-5. Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

 

Remedy

 

 

 

Unit does not work; pilot light not on.

 

Check fuse F1. Replace if open (see Section 5-2).

 

 

 

Erratic movement.

 

Check plug and terminal strip connections (see Sections 3-2 and 3-3).

 

 

 

Slide moves in only one direction.

 

Joystick or external device connections are incorrect (see Section 3-3).

 

 

 

 

 

 

 

 

 

Check joystick for proper operation and replace if necessary.

 

 

 

 

 

 

 

 

 

Check external device for proper operation and replace or repair.

 

 

 

Slide stalled and motor hums

 

Remove excessive load from gun mounting plate (see Section 2-3).

 

 

 

 

 

 

 

 

 

Check for part caught in slide or part stopping slide. Clear slide path.

 

 

 

 

 