SECTION 5 − INSTALLATION

5-1. Installing Welding Gun

4

3

12

.Be sure that gun end is tight against drive assembly.

3

3

1Drive Assembly

2Gun Securing Thumbscrew

3Gun End

Loosen thumbscrew. Insert end through opening until it bottoms against drive assembly. Tighten thumbscrew.

Welding gun must be inserted completely to prevent leakage of shielding gas.

4 Gun Trigger Leads

Insert leads, one at a time, through gun opening on front panel. Connect female friction terminals to matching male terminals in unit. Polarity is not important.

Close door.

 

Exposed O-rings

 

Incorrect

will cause shielding

Correct

gas leakage.

Gun Not Seated

 

Gun Fully Seated

803 711-A

5-2. Installing Work Clamp

 

 

 

 

 

 

. Connection hardware must be tightened with proper tools. Do not just

1

Nut

 

 

hand tighten hardware. A loose electrical connection will cause poor

2

Work Cable From Unit

 

weld performance and excessive heating of the work clamp.

3

Work Clamp

 

 

 

 

4

Screw

 

 

 

 

5

Work Clamp Tabs

 

 

 

Bend tabs around work cable.

 

 

 

6

Insulating Sleeves

 

 

 

Slide one insulating sleeve over

 

3

work cable before connecting to

1

 

clamp.

 

 

 

6

 

Slide

insulating

sleeves

over

 

handles.

 

 

2

 

 

 

 

 

 

5

4

 

 

 

 

 

Tools Needed:

 

 

 

 

 

 

7/16 in

 

 

 

 

 

 

7/16 in

 

 

 

 

802 456-A

 

 

 

 

 

OM-219 316 Page 12

 

 

 

 

 

 

Page 16
Image 16
Miller Electric MW 140 Plus, H-10 warranty Installation, Installing Welding Gun, Incorrect, Correct