Miller Electric OM-193 084E manual HE.L P-9, Voltmeter/Ammeter Help Displays

Models: OM-193 084E

1 36
Download 36 pages 4.78 Kb
Page 27
Image 27

5-3. Voltmeter/Ammeter Help Displays

VA

1

HE.L P–0

 

V

 

A

2

HE.L

 

P–1

 

 

 

 

 

 

 

V

 

A

3

HE.L P–2

 

V

 

A

4

 

 

 

HE.L

 

P–3

 

 

 

 

 

 

 

V

 

A

5

HE.L P–4

VA

6

HE.L P–5

 

V

 

A

7

HE.L

 

P–6

 

 

 

 

 

 

 

V

 

A

8

HE.L P–7

 

V

 

A

9

 

 

 

HE.L

 

P–8

 

 

 

 

 

 

 

V

 

A

10

HE.L P–9

.All directions are in reference to the front of the unit. All circuitry referred to is lo- cated inside the unit.

1 Help 0 Display

Indicates a shorted thermistor RT2 on the left side of the unit. If this display is shown, con- tact a Factory Authorized Service Agent.

2 Help 1 Display

Indicates a malfunction in the primary power circuit. If this display is shown, contact a Fac- tory Authorized Service Agent.

3 Help 2 Display

Indicates a malfunction in the thermal protection circuitry located on the left side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

4 Help 3 Display

Indicates the left side of the unit has over- heated. The unit has shut down to allow the

fan to cool it (see Section 3-2). Operation will continue when the unit has cooled.

5 Help 4 Display

Indicates a malfunction in the thermal protection circuitry located on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

6 Help 5 Display

Indicates the right side of the unit has over- heated. The unit has shut down to allow the fan to cool it (see Section 3-2). Operation will continue when the unit has cooled.

7 Help 6 Display

Indicates that the input voltage is too low and the unit has automatically shut down. Opera- tion will continue when the voltage is within the acceptable lower range limit (15% below the applicable input voltage). If this display is

shown, have an electrician check the input voltage.

8 Help 7 Display

Indicates that the input voltage is too high and the unit has automatically shut down. Operation will continue when the voltage is within the acceptable upper range limit (15% above the applicable input voltage). If this display is shown, have an electrician check the input voltage. Help 7 can also indicate a bus voltage imbalance.

9 Help 8 Display

Indicates a malfunction in the secondary power circuit of the unit. If this display is shown, contact a Factory Authorized Ser- vice Agent.

10 Help 9 Display

Indicates a shorted thermistor RT1 on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

OM-193 084 Page 23