Miller Electric OM-193 084E manual Electrical Service Guide, Connecting Input Power

Models: OM-193 084E

1 36
Download 36 pages 4.78 Kb
Page 21
Image 21

3-7. Electrical Service Guide

NOTE

Actual input voltage should not exceed ± 10% of indicated required input voltage. If actual input voltage is outside of this range, output may not be available.

Input Voltage

460

 

 

Input Amperes At Rated Output

18.5

 

 

Max Recommended Standard Fuse Or Circuit Breaker Rating In Amperes

30

 

 

Reference: 1996 National Electrical Code (NEC).

S-0092J

 

 

3-8. Connecting Input Power

Check input voltage available at site.

1 Input And Grounding

Conductors

2 Line Disconnect Device

Select type and size of overcurrent protection using Section 3-7.

Y Always connect green/yel- low wire to supply ground- ing terminal, never to a line terminal.

2

L1

L2

L3

Green

1

YAlways connect grounding conductor first.

1

= GND/PE

Tools Needed:

Input_9_99 / Ref. ST-144 221 / ST-801 192

OM-193 084 Page 17

Page 21
Image 21
Miller Electric OM-193 084E manual Electrical Service Guide, Connecting Input Power