SECTION 4 − INSTALLATION

4-1. Specifications

 

Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum

Model/Rated

Volts @

Amperes

 

 

Rated Cutting

Type of

Plasma Gas

@ Rated

 

 

Open-Circuit

Output

KVA

KW

Capacity

Output

50/60 Hz,

Cutting

 

Voltage DC

 

3 Phase

 

 

 

 

 

 

Capacity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7/8 in

Direct

 

 

UPC 838

380

21.6

14.21

13.50

(22 mm)

 

 

 

 

 

 

At 10 IPM

Current,

Air Or Nitrogen

 

80 A @ 112

 

 

 

 

350

 

 

 

 

 

Straight

Volts DC, 60%

 

 

 

 

 

Only

 

 

 

 

7/8 in

 

 

 

 

Polarity

 

Duty Cycle

440

19.3

14.71

13.9

(22 mm)

 

 

(DCEN)

 

 

 

 

 

 

 

 

 

 

At 10 IPM

 

 

 

 

 

 

 

 

 

 

 

 

4-2. Duty Cycle And Overheating

Three-Phase Input Power:

60% Duty Cycle

Duty Cycle is percentage of 10 min- utes that unit can cut at rated load without overheating.

If unit overheats, thermostat(s) opens, output stops, and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or duty cycle before cutting.

YExceeding duty cycle can damage unit and void war- ranty.

6 Minutes Cutting

4 Minutes Resting

Overheating

0

A

15

OR

MinutesReduce Duty Cycle

duty1 4/95

OM-202 515 Page 12

Page 16
Image 16
Miller Electric UPC 838 manual Installation, Specifications, Duty Cycle And Overheating