FUNCTIONAL DESCRIPTION
ASSEMBLY
1 | 1. | Laser window |
2 | 2. | Display |
3. | Keypad | |
| 4. | Battery compartment |
6 | 5. | End bracket |
6. | Nameplate | |
5 | 7. | Laser "ON" |
8. | Reference |
Loading/Changing the batteries
Replace the batteries when the symbol flashes permanently in the display. Only use alkaline batteries. If the meter will not be used for a long time, remove the bat- teries as a protection against corrosion.
1.To open the compartment lid, twist a coin pressed into compartment slot.
2.Insert two (2) AAA batteries, as displayed.
3.Replace compartment lid securely.
| 4 |
|
|
| (front/rear/end bracket) | |
3 | 9 10 | 11 | 12 | 13 | ||
|
OPERATION
|
|
| 9. Pythagorean |
7 |
|
| 10. Timer |
8 |
| 14 | 11. Historical memory |
| 15 | 12. Area/Volume | |
19 |
| 13. Battery status | |
18 |
| 16 | 14. Units with exponents (2/3) |
| 15. Intermediate line 2 | ||
|
| 17 | 16. Intermediate line 1 |
20 |
| 17. Main targets | |
|
| 18. Min/Max display | |
|
| 6 | |
|
| 19. Display notice symbol | |
21 | 28 |
| 20. On/Measure button |
| 21. Add (+) button | ||
22 | 27 |
| 22. Function button |
| 23. Memory button | ||
|
| Made In Hungary | 24. Backlight button |
23 | 26 |
| |
READ OPERATOR’S MANUAL | 25. Clear/Off button | ||
|
| 26. Timer/Units button | |
24 |
|
| |
25 | MAXIMUM POWER <1mW WAVE LENGTH | 27. Reference button | |
CLASS II LASER PRODUCT COMPLIES WITH 21 | 28. Subtract | ||
|
| CFR 1040.10 AND 1040.11 | |
|
|
|
SYMBOLOGY
| Laser product |
Volts Direct Current | Avoid Exposure: Laser Radiation |
| Is Emitted From This Aperture |
CAUTION Laser Light - | To reduce the risk of injury, user |
Do Not Stare Into Beam | must read operator’s manual. |
| 4 |
Button use
For some buttons, the way it is pressed determines its function. These terms ap- pear throughout the operation section:
PRESS - press and release the button briefly.
PRESS and HOLD - press in and hold the button for 2 seconds.
Switching on/off
Press the button once to turn on the meter and laser.
The symbol is displayed until the next button is pressed.
Press and hold the button to turn off the meter.
The meter turns off automatically after three minutes of
Backlight
Press the button to turn the display backlight on or off.
Selecting the units
Press and hold the button to change the measurement units. Repeat to scroll through the settings. Possible units:
Setting Distance Area Volume
- - - m 0.000 m 0.000 m² 0.000 m³
- | 0'0'' 1/16 | 0.00 ft² | 0.00 ft³ |
|
- - - in | 0 in 1/16 | 0.00 ft² | 0.00 ft³ |
|
- - - ft | 0.00 ft | 0.00 ft² | 0.00 ft³ | 5 |
|
|
|
|
Timer
1. Press the button to set the timer
to 5 seconds. Use the or buttons to change the time lapse.
2.On the first measurement, the count- down begins immediately. For addi- tional measurements, press the button to begin the
3.When the timer reaches 5 seconds, it will begin to beep.
4.When the timer reaches 0, the mea- surement is taken.
Clearing last entry
Press the button to clear the last action.
Turning the beep on and off
1.Press and hold the and but- tons together for 5 seconds.
2.The beep is turned on or off.
Memory recall
1.Press the button to display the latest value (measured or calcu- lated).
2. Use the | or |
|
| buttons to scroll |
|
| |||
through the last | 10 values (measured |
and calculated). The values can also be used in functions.