Charge only MILWAUKEE 12, 14.4 and 18 Volt battery packs in this charger. Other types of batteries may explode causing

personal injury and damage.

Charging the Battery Pack

Connect Charger to AC Power Source

Light Off

Charger Ready

When to charge the battery pack

Charge your battery pack before you use your tool for the first time and when your tool no longer performs with the power and torque needed for the job. Never com- pletely discharge the battery pack.

New battery packs reach full loading ca- pacity after 4-5 chargings and dischargings. Battery packs which have not been used for some time should be recharged before use.

Standard charging times

Standard charging time is approximately one hour. Charging time varies depending on the battery temperature, charge needed

Automatic start

When a hot or cold battery pack is inserted into the charger, charging will begin auto- matically if the battery reaches the correct charging temperature.

Maintenance charge

Batteries discharge at a rate of about 1% per day. The Maintenance Charge feature keeps the battery pack fully charged when the battery pack is stored in a charger that is plugged in. The Maintenance Charge automatically begins after the battery pack is fully charged. During Maintenance Charge,the control light will be off.

Insert Battery

Flashing Light

Flashing Light

Battery too hot

Battery too cold

over 113°F (45°C)

less than 41°F (5°C)

and the type of battery pack being charged. For example, if the battery pack does not require a full charge, the charg- ing time will be less than one hour.

Effects of temperature on charging

Battery packs are affected by temperature. The charger will sense battery temperature and will charge the battery at the most rapid rate when its temperature ideal (between 41°F (5°C) and 113°F (45°C). When the battery temperature is outside of this range, the charger will supply enough current to keep the battery pack in its current state to prevent damage to battery.

Charge pending until battery temperature is below 113°F (45°C).

Continuous Light

Battery temperature 41°F - 113°F (5°C - 45°C) Charging

Light Off

Battery is charged/

Maintenance charging

Charge pending until battery temperature is above 41°F (5°C).