6-8
4. When the Message “Misfeeding is detected.” Appears
When a Message Appears Chapter 6

Misfeed Clearing Procedures

Remove the original stack from the
Document Feed Tray.
Swing open Document Feed Unit Door
and gently pull out the original.
Holding down the Lock Release Button,
swing open Document Turnover/Exit Unit
Door and carefully pull out the
original from the Exit Unit.
Close and .
Raise the Duplexing Document Feeder.
Opening the Document Turnover/Feed Unit
Guide Plate, gently pull out the original from
the Unit.
Remove the original from the Original Glass
and lower the Duplexing Document Feeder.
When the message “Re-insert the following
# of originals” is shown on the Display,
return the number of originals indicated on
the Display to the bottom of the original
stack removed in step 1 and reload it onto
the Document Feed Tray.
Duplexing Document Feeder
1
1151O097AA
2F1
1151O031AA
3
F2
1151O032AB
4F1 F2
5
1151O033AA
6
1139O0840A
7
1151O098AA
1154O039AA