22 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Electrical Connections:* The breaker supplying electricity to the fireplace must be turned off at the
electrical panel before any connections are made at the fireplace.
* The wire supplying the fireplace should be a minimum of 14 gage and
provide 120 Volts at 60 hz.
* The fireplace must be grounded in accordance with local electrical
codes or, in the absence of local codes, with the National Electrical
Code or ANSI/NFPA 70 - latest edition.
* The electrical box is located at the right rear of the fireplace (see Figures
29 and 30). Remove the cover, loosen the wire clamp A and feed the
household supply line through the clamp and retighten clamp.
* Connect the supply ground wire to the green screw B.
* Remove the wire nut C from the black wires coming from the fireplace
and join these wires to the black supply wire reusing the wire nut.
Repeat for white wires.
* Reinstall the cover to the fireplace.
* If a wall-mounted burner on/off switch or thermostat is to be used,
the wires running from the switch or thermostat should be routed to
the left side of the fireplace. The wire should be fed through the gas
line supply hole along the gas line to the valve.
Wall-Mounted Fan Speed Control: If desired, a wall-mounted fan speed control can be installed. The breaker
supplying electricity to the fireplace must be turned off at the electrical
panel before any connections are made. The loop of wire with the label
attached (E in Figure 29) may be cut and the wire leads from the wall-
mounted speed control connected to each end of the cut wire.
Optional Heat Ducting System:The remaining red and white wires with capped ends (wires D in Figure
29) are for the optional Forced Air Heating System. See the instructions
provided with the system for installation details.
Figure 29Figure 30Figure 31L
a
be
l
L
a
b
e
l
D
A
C
E
B
Fan Wiring DiagramGreen (Ground)
Snap Switch (Contacts Close When Fireplace is Hot)
Black (Hot)
From Power Source
Speed Control
White (Neutral)
Black
Black
Red
White
Blower
To Optional Heat Duct Fan