38 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
IGNDATE OF MANUFACTURE
20082010 20112009JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
CAUTI ON: HOT WHI LE IN OPER ATION. DO NO T TOUC H. SE VERE BURNS MAY RES ULT. KEEP
CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY.
KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS
ACCOMPANYING APPLIANCE. FOR USE WITH GLASS DOORS CERTIFIED WITH THIS APPLIANCE ONLY. DO NOT
OPERATE THE APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S)
SHOULD BE DONE BY A LICENSED OR QUALIFIED PERSON.
WARNING:IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE. REFER TO THE OWNER’S INFORMATION MANUAL PROVIDED WITH THIS
APPLIANCE. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE
AGENCY OR GAS SUPPLIER.
MODELMODÈLERAVELLE™ 42MANUFACTURED BY / FABRIQUÉ PAR:LENNOX HEARTH PRODUCTSPO BOX 987AUBURN, WA., USA 98071RAVL42SERIAL NO.Report No. / Número de Rapport050-S-08c-5LISTED VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELTESTED TO ANSI Z21.88-2005/CSA 2.33-2005 “VENTED GAS FIREPLACE HEATERS”, UL307b, CSA P.4.1-02, AND CGA 2.17-M91.THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT ANSI Z223.1/NFPA 54-LATEST EDITION (USA) OR CAN/CGA B149.1-LATEST EDITION (CANADA). THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION INSTRUCTION. FOR INSTALLATION IN SOLID FUEL BURNING FIREPLACES ONLY - MASONRY OR FACTORY BUILT. THIS VENTED GAS FIREPLACE HEATER IS NOT FOR USE WITH AIR FILTERS. THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN AN AFTERMARKET, PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME WHERE NOT PROHIBITED BY LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES UNLESS A CERTIFIED KIT IS USED. MAY BE INSTALLED IN RESIDENTIAL BEDROOMS.DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.IF ELECTRICALLY CONNECTED, CONNECTIONS AND GROUNDING MUST BE IN ACCORDANCE WITH LOCAL CODES, IF ANY. IF NOT, FOLLOW THE CURRENT NATIONAL ELECTRICAL CODE ANSI/NFPA 70-LATEST EDITION (USA) OR CSA C22-1-LATEST EDITION (CANADA).DO NOT REMOVE OR COVER THIS LABELPart No./ No. pièce #36202 Rev. A, 06/2007FACTORY EQUIPPED FOR NATURAL GAS. IF CONTROL PANEL CONTRADICTS THIS LABEL, UNIT FUEL TYPE HAS BEEN CONVERTED.CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.MINIMUM CLEARANCES TO COMBUSTIBLES IN INCHESFront corners to enclosure (from stand-offs) 0 Hearth Extension - not required but recommendedBack to enclosure (from stand-offs) 0 Rear corners to enclosure (from stand-offs) 0Top to header (from stand-offs) 0 Base of unit to mantel 47-5/8Bottom of unit to floor 0 Base of unit to top trim/facing 41-5/8Side trim or wall to edge of door glass 7.5See owner’s manual for additional clearance information on mantels and direct vent pipe.NG LP NG LPInput Rate on “HI” (BTU/H) 42,000 36,000 Minimum Inlet Pressure (in. WC) 5 11Input Rate on “LO” (BTU/H) 29,500 25,000 Manifold Pressure on “HI” (in. WC) 3.5 10Orifice Size (DMS) #30 #49 Manifold Pressure on “LO” (in. WC) 1.7 5.1Blower Electrical Rating: 120 VAC, 60 Hz, Less Than 2 Amps*Unit factory equipped for 0-2000 ft/0-610 m, in Canada 0-4500 ft/0-1370 M. For altitudes above 2,000 ft/610m (in Canada 4500 ft/1370m) de-rate the appliance by four (4)% for every 1,000 ft (405 m).See owner’s manual for instructions on changing cassette/valve assembly.
HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - INSERTION DE FOYER AU GAZ - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDETESTÉ SELON LA NORME ANSI Z21.88-2005/CSA 2.33-2005 «FOYER RADIANT AU GAZ», UL307B, CSA P.4.1-02, ET CGA 2.17-M91.CET APPAREIL DOIT ÊTRE INSTALLÉ CONFORMÉMENT AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI NFPA 54-DERNIÈRE ÉDITION (ETATS-UNIS), OU CAN/CGA-B149.1-DERNIÈRE ÉDITION (CANADA). CET APPAREIL DOIT ÊTRE INSTALLÉ SELON LES DIRECTIVES D’INSTALLATION DU FABRICANT. POUR INSTALLATION DANS DES FOYERS À COMBUSTIBLE SOLIDE SEULEMENT - DE MAÇONNERIE OU PRÉFABRIQUÉ EN USINE. CE FOYER RADIANT AU GAZ À ÉVACUATION N’EST PAS CONÇU POUR ÊTRE UTILISÉ AVEC DES FILTRES À AIR. CET APPAREIL DOIT ÊTRE UTILISÉ AVEC LE TYPE DE GAZ INDIQUÉ SUR LA PLAQUE SIGNALÉTIQUE ET PEUT ÊTRE INSTALLÉ DANS UNE MAISON PRÉUSINÉE OU DANS UNE MAISON MOBILE FIXE, LÀ OÙ LES CODES RÉGIONAUX LE PERMETTENT. VOIR LE MANUEL D’ENTRETIEN POUR PLUS DE DÉTAILS. CET APPAREIL NE PEUT PAS ÊTRE CONVERTI POUR L’USAGE AVEC D’AUTRES TYPES DE GAZ À MOINS D’UTILISER UNE TROUSSE DE CONVERSION HOMOLOGUÉE.DANGER: RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHEZ L’APPAREIL AVANT D’EN FAIRE L’ENTRETIEN.SI L’APPAREIL REQUIERT UN BRANCHEMENT ÉLETRIQUE, LES RACCORDEMENTS ET LA MISE À LA TERRE DOIVENT ÉTRE CONFORMES AUX EXIGENCES DES CODES RÉGIONAUX ET DU CODE D’INSTALLATION ANSI/NFPA 70 OU CSA C22-1.
DANGER: CET APPAREIL DÉGAGE DES TEMPÉRATURES ÉLEVÉES ET DEVRAIT ÊTRE INSTALLÉ À L’ÉCART DES
ENDROITS TRÈS PASSANTS ET LOIN DES MEUBLES ET RIDEAUX. SURVEILLEZ LES ENFANTS QUI SE TROUVENT DANS LA PIÈCE. GARDEZ LA ZONE AUTOUR DU FOYER EXEMPTE DE MATÉRIAUX COMBUSTIBLES, D’ESSENCE ET AUTRES VAPEURS ET LIQUIDES INFLAMMABLES. MAINTENEZ LE BRÛLEUR ET LE BOÎTIER DES COMMANDES PROPRE EN TOUT TEMPS. VOIR LES MANUELS D’INSTALLATION ET D’ENTRETIEN QUI ACCOMPAGNENT L’APPAREIL. SEUL LE PANNEAU VITRÉ FOURNI PAR LE MANUFACTURIER PEUT ÊTRE UTILISÉ AVEC CET APPAREIL. EN AUCUN CAS, L’APPAREIL NE PEUT ÊTRE UTILISÉ SANS LA VITRE OU AVEC LA VITRE BRISÉE. LE REMPLACEMENT DE LA VITRE DOIT ÊTRE EFFECTUÉ PAR UN TECHNICIEN DE SERVICE QUALIFIÉ.AVERTISSEMENT:UNE INSTALLATION INADÉQUATE DE MÊME QU’UN AJUSTEMENT, UNE MODIFICATION, UNE RÉPARATION OU UN ENTRETIEN INCORRECTS PEUVENT CAUSER DES BLESSURES OU DOMMAGES À LA PROPRIÉTÉ. RÉFÉREZ-VOUS AU MANUEL D’ENTRETIEN LIVRÉ AVEC CET APPAREIL. POUR DE L’ASSISTANCE, CONSULTEZ UN INSTALLATEUR QUALIFIÉ, UNE ENTREPRISE DE SERVICE OU UN FOURNISSEUR DE GAZ.IGN 07-2554N’ENLEVEZ PAS OU NE COUVREZ PAS CETTE ÉTIQUETTE
SPÉCIFICATIONS
NG LP NG LP
Entrée Max/min BTU/hr 0-4500 Pi (0-1370 M)*
42,000 36,000 Pression Minimum D’entrée Du Gaz
(IN. WC/C.E.)
5 11
Entrée Minimum BTU/hr 0-4500 Pi (0-1370 M)*
29,500 25,000 Pression À La Sortie - HI
(IN. WC/C.E.)
3.5 10
Orifice (DMS)* #30 #49 Pression À La Sortie - LO
(IN. WC/C.E.)
1.7 5.1
Spécifications Électrique 120 Vca, 60 Hz, Moins De 2 Ampères
*En altitude, au-delà de 2000 pi/610 m, (au canada 0-4500 pi/0-1370m) la capacité énergétique de l’appareil diminue de quatre (4)% pour chaque
1000 pi (405 m).
Référez-vous au manuel d'instructions du propriétaire pour changer le bloc d'assemblage de la valve.
DÉGAGEMENTS AUX COMBUSTIBLES - EN POUCES (MILLIMÈTRES)
Coins avant au caisson (depuis les espaceurs) 0 (0mm) Extension d’âtre - Prolongement de l'âtre - Non requis mais recommandé
Du dos au caisson (depuis les espaceurs) 0 (0mm)Côtés arrière au caisson (depuis les espaceurs) - 0 (0mm)
Du dessus au support (depuis les espaceurs) 0 (0mm) De la base de l’unité au manteau - 47-5/8"" (1210mm)
Du fond de l’unité au plancher 0 (0mm) De la base de l’unité à la finition/ façade du dessus - 41-5/8" (1057mm)
De la finition du côté ou du mur au bord de la vitre 7-1/2 (191mm)
Voir le manuel d’installation pour plus d’informations sur les dégagements requis au manteau, conduits direct-vent et prolongement de
l’’âtre.
MODELMODÈLERAVELLE™ 42
MANUFACTURED BY / FABRIQUÉ PAR:
LENNOX HEARTH PRODUCTS
PO BOX 987
AUBURN, WA., USA 98071
SERIAL NO.
Report No. / Número de Rapport
050-S-08c-5
No. pièce #36264 Rev. A, 06/2007
CET APPAREIL EST MUNI D’ÉQUIPEMENT POUR L’USAGE DU GAZ NATUREL. SI L’ÉTIQUETTE DU PANNEAU DES COMMANDES CONTREDIT CETTE
ÉTIQUETTE, C’EST QUE LE TYPE DE CARBURANT DE CET APPAREIL A ÉTÉ CONVERTI.
Le numéro de série est indiqué dans
la section anglophone de cette étiquette
Le date de fabrication est indiquée dans la section anglophone de cette étiquette
US
Portland
US
Portland

SAFETY / LISTING LABEL - FRENCH

SAFETY / LISTING LABEL - ENGLISH

2009 2010 2011 2012