Mio SELF CLEAN C SERIES II, STANDARD owner manual Safety Notice, Maintenance Of Power Supply

Models: SELF CLEAN C SERIES II STANDARD

1 12
Download 12 pages 37.36 Kb
Page 7
Image 7

Terminal Block the coloured wires from your pool light are connected. The Light Transformer is for use with 12volt pool lights, maximum power is 150Watt.

Please Note: Only one light can be connected to each light transformer. If more than one light is required please refer to your Aquachlordealer.

SAFETY NOTICE

IMPORTANT Certain local electrical regulations state “If the supply cord is damaged, it must be replaced by a special cord available from the manufacturer or its service agent”.

MAINTENANCE OF POWER SUPPLY:

Little or no maintenance is normally required with the exception of replacing blown Fuses. These 3 Amp Fuses (5amp for C520) can be sourced from your local AquachlorDealer. However it is essential that the wall or post to which the Unit is installed be sprayed (not the Unit itself) periodically with a good surface type insect repellent, since penetration by insects may cause damage which is not covered by your warranty.

The Unit will become warm to hot when in operation, this is normal.

MAINTENANCE OF ELECTROLYTIC CELL:

The cell is composed of extremely expensive materials, and although proper maintenance can prolong its life to the maximum, eventually the process of electrolysis will wear away its delicate coating, at which time it gradually ceases to produce chlorine.

Mineral salts and calcium (scale) are deposited on the outer and the inner plates as electrolysis takes place. This build up will interfere with the flow of electrical current in the Cell and thus lowers sanitiser production. It is essential to inspect the Cell regularly and clean when necessary. The rate at which deposits will form on the plates differs with each pool and can be influenced by the following:

Calcium hardness of the water Water Temperature

pH control

Water which has been chlorinated with calcium hypochlorite for an extended period

Calcium in the plaster surfaces of a concrete pool

Because these conditions vary so much, check the Cell at least weekly to begin with to see when either scale or a blue/green soapy substance appears on the plates. You will then be able to determine the cleaning cycle necessary for your pool (obviously more in summer). The intervals between cleaning could get longer to the point where cleaning is only necessary a few times each year. One exception is the use of bore water or ground water, in which case cleaning may always need to be as frequent as once a week.

Life of Aquachlorelectrolytic cells will vary substantially from one installation to another due to variations in operating time, water quality and composition, system and cell maintenance. Please ensure that when cell replacement is necessary you use the correct genuine Aquachlorreplacement cell to match your system.

7

Page 7
Image 7
Mio SELF CLEAN C SERIES II, STANDARD Safety Notice, Maintenance Of Power Supply, Maintenance Of Electrolytic Cell