IMPORTANT: ALWAYS INSIST ON GENUINE AQUACHLOR REPLACEMENT PARTS. If it is necessary to replace the Electrolytic Cell, beware of “look alikes”. Only the Genuine Aquachlor Cell is designed and warranted to operate with the Aquachlor Power Supply.

SERIOUS DAMAGE MAY RESULT TO THE ELECTRONICS INSIDE THE UNIT IF COPY ELECTRODES ARE USED AND WILL VOID WARRANTY.

PATENT INFORMATION: AquachlorSelf Clean Sytems are protected by Australian Standard

Patent Number 684550.

Consult your local Aquachlor Dealer for further information.

TROUBLE SHOOTING:

No Chlorine Production - Check for

1.Main power outlet switched off

2.Chlorinator not plugged into main outlet

3.Pump not plugged into Chlorinator

4.Time Clock set to Off position/Power switch turned Off

5.System Control turned to mid setting

6, Chlorinator 3 amp fuse blown

7.Dirty Cell

8.Filter needs backwashing

9.Gas Sensor not connected

10.Running times incorrect

11.Main house fuse blown

12.Pump motor faulty

Low Chlorine Production - Check for

1.Dirty Cell - clean if required

2.Filter needs backwashing

3.Display not at correct production level/Cell failing

4.Winter Mode turned On

5.Pool stabiliser too low

6.pH too high

7.Salt level too low

8.Aquachlor running time inadequate

Technical Information (specifications subject to change without notice):

Model

Output

100%

Fuse

Approximate

 

(grams per hour)

 

Power

 

 

 

 

Consumption (W)

C260

20

 

3A

200

C390

30

 

3A

300

C520

40

 

5A

400

SC250

16

 

3A

160

SC330

24

 

3A

240

12

Page 12
Image 12
Mio STANDARD, SELF CLEAN C SERIES II owner manual Trouble Shooting, No Chlorine Production Check for