Introduction
This document describes the configuration of Mitel Networks PBX’s to correctly interface to the Interactive Group Communication System by VCon. For more information on the configuration of the IGC, please refer to Mitel 3300 - RemoteAbility IGC Integration Specifications V1. Note that all PBX configuration should be undertaken by a qualified Technician.
3300ICP with ISDN or SX2000 with ISDN
∙Attach VCon IGC server T1 link to NSU, DSU or Embedded PRI card
oConfigure hardware for Line Termination through jumpers or DIP switch – please refer to the Technician’s Handbook of the correct product (3300 or SX2000)
∙connect to server with a straight through cable
∙Program trunks
ofor example, please see Example of T1 PRI programming on 3300
∙Program PRI link characteristics though IMAT (for NSU or DSU) or through ESM (embedded PRI card in 3300ICP)
oProtocol used is
∙Reset NSU or PRI card to allow new configuration to load
∙Test link to server by dialing <feature access code for individual trunk access> <trunk number><any 4 digit number>< # > e.g. <**2><6101><1000><#>
oYou should hear “Welcome to Remoteability”
∙Program ARS so that a single four digit number accesses the IGC system
oProgram trunk group
oAdd trunks to trunk group
oCreate Digit Modification Assignment o Create Route Assignment
oCreate ARS Digits Dialed Assignment
oPlease see Example of ARS Programming on 3300 or SX2000
Example of T1 PRI programming on 3300 or SX2000
Class Of Servic e – changes from default values
Public Network Access via DPNSS | Yes |
7/4/2004 | Page 3 of 22 |