ITEM | MODEL |
|
| PC24EK | PC30EK | PC36EK | PC42EK | PCH24EK | PCH30EK |
| PCH36EK | PCH42EK |
| Cooling | *1 BTU/h | 24,000 | 31,000 | 36,500 | 42,500 | 24,000 | 30,000 |
| 35,400 | 42,000 | |
Capacity | Heating | *1 BTU/h | — | — | — | — | 27,000(33,500) | 33,000(41,500) |
| 38,000(47,600) | 43,000(52,600) | |
| Heating | *2 BTU/h | — | — | — | — | 18,400(24,900) | 18,000(26,500) |
| 19,600(29,200) | 24,800(34,400) | |
Power | Cooling | *1 kW | 2.43 | 3.1 | 3.8 | 4.4 | 2.46 | 3.06 |
| 3.53 | 4.37 | |
Consumption | Heating | *1 kW | — | — | — | — | 2.42(4.32) | 3.13(5.63) |
| 3.4(6.2) | 4.3(7.1) | |
| Heating | *2 kW | — | — | — | — | 2.1(4.0) | 2.6(5.1) |
| 2.7(5.5) | 3.2(6.1) | |
EER |
| *1 |
| 9.9 | 10.0 | 9.6 | 9.7 | 9.8 | 9.8 |
| 10.0 | 9.6 |
SEER |
|
|
| 10.3 | 10.4 | 10.2 | 10.0 | 10.3 | 10.0 |
| 10.4 | 10.0 |
HSPF |
|
|
| — | — | — | — | 7.1 | 7.1 |
| 7.4 | 7.3 |
COP | Heating | *1 |
| — | — | — | — | 3.3 | 3.1 |
| 3.3 | 3.1 |
| Heating | *2 |
| — | — | — | — | 2.6 | 2.4 |
| 2.1 | 2.3 |
INDOOR UNIT |
|
|
| PC24EK | PC30EK | PC36EK | PC42EK | PCH24EK | PCH30EK |
| PCH36EK | PCH42EK |
External Finish |
|
|
|
|
|
| Munsell 2.5Y 8/0.3 & N2 |
|
|
|
| |
Power Supply | V, phase, Hz |
|
| 115, 1, 60 |
|
|
|
| 230, 1, 60 |
| ||
Max. Fuze Size (time delay) | A | 15 | 15 | 15 | 15 | 20 | 25 |
| 25 | 25 | ||
Min. Ampacity | 3 |
|
| 3 | 3 | 3 | 12 | 15 | 15 |
| 17 |
|
Fan Motor |
| F.L.A. | 1.8 | 1.8 | 2.1 | 2.4 | 0.7 | 0.7 |
| 1.3 | 1.3 | |
Auxiliary Heater |
| A (kW) | — | — | — | — | 8.4(1.9) | 10.8(2.5) |
| 12(2.8) | 12(2.8) | |
Airflow | Dry |
| CFM |
| ||||||||
| Wet |
| CFM |
| ||||||||
Moisture Removal | Pints/h | 7.2 | 9.6 | 11.1 | 12.6 | 7.0 | 9.1 |
| 10.9 | 12.3 | ||
Sound Pressure Level | dB(A) |
| ||||||||||
Cond. Drain Connection OD | in. | 1 | 1 | 1 | 1 | 1 | 1 |
| 1 | 1 | ||
| W |
| in. |
| ||||||||
Dimensions | D |
| in. |
| ||||||||
| H |
| in. |
| ||||||||
Weight |
|
| lbs. | 93 | 93 | 115 | 115 | 97 | 97 |
| 119 | 119 |
OUTDOOR UNIT |
|
| PU24EK | PU30EK | PU36EK | PU42EK | PU24EK | PU30EK |
| PU36EK | PU42EK | |
External Finish |
|
|
|
|
|
| Munsell 5Y 7/1 |
|
|
|
| |
Sound Pressure Level |
| dB(A) | 55 | 55 | 55 | 56 | 55 | 55 |
| 55 | 53 | |
Power Supply | V, phase, Hz |
|
|
| 230, 1, 60 |
|
|
|
| |||
Max. Fuze Size (time delay) | A | 20 | 30 | 30 | 40 | 20 | 30 |
| 30 | 40 | ||
Min. Ampacity | 16 |
|
| 20 | 22 | 27 | 16 | 20 | 22 |
| 27 |
|
Fan Motor |
| F.L.A. | 0.65+0.65 | 0.65+0.65 | 0.75+0.75 | 0.8+0.8 | 0.65+0.65 | 0.75+0.75 |
| 0.75+0.75 | 0.8+0.8 | |
| Model (Type) | NH33NBD | NH41NAD | NH47NAD | NH569NXA | NH33NBD | NH41NAD |
| NH47NAD | NH569NXA | ||
Compressor | R.L.A.11.5 |
| 14 | 17.5 | 20 | 11.5 | 14 | 17.5 |
| 20 |
| |
| L.R.A.54 |
|
| 73 | 87 | 105 | 54 | 73 | 87 |
| 105 |
|
Crankcase Heater |
| A(W) | .17(39) | .17(39) | .17(39) | .17(39) | .17(39) | .17(39) |
| .17(39) | .17(39) | |
Refrigerant Control |
|
|
|
|
| Capillary Tube |
|
|
|
| ||
Defrost method |
|
|
| — |
| — |
|
| Reverse Cycle |
|
| |
| W |
| in. |
| ||||||||
Dimensions | D |
| in. |
| ||||||||
| H |
| in. |
| ||||||||
Weight |
|
| lbs. | 207 | 208 | 220 | 260 | 202 | 245 |
| 246 | 268 |
REMOTE CONTROLLER |
|
|
|
|
| With Indoor Unit |
|
| ||||
Control Voltage (by built- in transformer) |
| Indoor |
|
Figures in parentheses include auxiliary heat.
* For 208 volt applications refer to Technical And Service Manual for ratings.
18