4.24.3 PID set point direct setting menu
The setting menu is used to input the PID set point (Pr. 133, Pr. 755) in simple steps under PID control.
Pressing while the FR-PU07-01 is in the monitor mode starts the direct setting mode for the PID set point.
(Valid under PID control. If is pressed while the PID control is invalid, the function menu is displayed.)
REMARKS
In the direct setting mode, parameters can be always read or written regardless of the Pr. 77 and Pr. 160 settings.
PIDset
0. 0 PSI
-- - S TOP HAND
Monitor mode Function menu
1 MONITOR
2 PU Oper
3 Pr.List
4 Pr.Clear
PIDset pnt1
SET 80.0PSI
FUNC:FUNC MENU
Direct setting mode 1 (Pr. 133)
Direct setting mode 2 (Pr. 755)
Direct setting mode 1 (Pr. 133)
PIDset pnt1
SET 80.0PSI
SET
0~500
PIDset pnt2
SET
0~500
Direct setting mode 2 (Pr. 755)
Change the value with the numeric keypad.
Writing of the set value is completed.
The setting is applied to the PID action.
Writing of the set value is completed.
The setting is applied to the PID action.