Mr.SLIM Multi - System
Multiple (2,3 & 4) indoor units can be operated simultaneously with a single outdoor unit.
Twin allows the simultaneous operation of 2 indoor units on one floor.
Triple can cover a large scale space or dispersed insallation on the same floor.
Advantages of
Mr.SLIM Multi - System
1)Equally comfortable air conditioning for big space with multiple indoor units.
The simultaneous operation of up to 4 indoor units is possible. Optimum airflow distribution can be realized even in a large space thus providing comfort uniformly in the entire room. This feature is best suited to be applied to rooms likely having uneven temperature distribution, building floors requiring dispersed installation of indoor units, and large halls.
System example
89
Quadruple can realize the optimum temperature distribution even in a large space.
2) Various indoor unit combinations available.
-Combination pattern of indoor units
Same capacity - Same type
Same capacity - Different type
As different types such as the cassette type and the ceiling suspended type are possible to be combined, a
*The height difference between the indoor units must be less than 1m.
3)Automatic address setting for easy installation. Refrigerant address setting for each indoor unit is not needed. This has contributed in shortening the wiring work time and improving reliability significantly.
4)Reduction of installation space of outdoor unit.
2 to 4 indoor units require only 1 outdoor unit, thus reducing the installation space.
All indoor units
can be controlled by 1 remote controller
Procedure of selection
Selection of Outdoor unit |
| Selection of Indoor unit |
| Selection of Distribution Pipe |
|
|
|
|
|
Please choose an outdoor unit with capacity |
| Please choose indoor units (2~4 sets) taking | Please choose one set of the Distribution | |
to cover the size (air conditioning load) of the |
| into account the configuration of installation | Pipe (option) in compliance with a combined | |
installation space. |
| spaces and load conditions. | capacity ratio of the indoor units. |
Combination chart
Mr. SLIM Inverter |
|
|
| Mr. SLIM |
|
|
| ||||||||||
Outdoor unit | Twin | Triple | Quadruple |
| Outdoor unit | Twin | Triple | Quadruple | |||||||||
Capacity | 50 : 50 | 33 : 33 | : 33 | 25 : 25 : 25 : 25 |
| Capacity | 50 : 50 | 33 : 33 : 33 | 25 : 25 : 25 : 25 | ||||||||
|
|
| |||||||||||||||
71 | 35 x 2 |
|
|
|
|
|
|
|
| 71 | 35 x 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
100 | 50 x 2 |
|
|
|
|
|
|
|
| 100 | 50 x 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
125 | 60 x 2 |
|
|
|
|
|
|
|
| 125 | 60 x 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
140 | 71 x 2 | 50 x | 3 |
|
|
|
| 140 | 71 x 2 | 50 x 3 |
|
|
| ||||
|
|
|
|
|
|
| |||||||||||
200 | 100 x 2 | 60 x | 3 | 50 x 4 |
| 200 | 100 x 2 | 60 x 3 | 50 x 4 | ||||||||
250 | 125 x 2 | 71 x | 3 | 60 x 4 |
| 250 | 125 x 2 | 71 x 3 | 60 x 4 | ||||||||
Distribution pipe |
| Distribution pipe | |||||||||||||||
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor unit
4 way cassette Ceiling concealed Wall mounted Ceiling suspended Floor standing | Kitchen |
|
|
35
50
60
71
100
125
*Floor standing type can not be connected together with the indoor units of different type.
**With heater type indoor units can not be combined with those without heater.
Outdoor unit
Outdoor Unit (capacity)
71 | 100 | 125 | 140 | 200 | 250 |
|
|
|
|
|
|
Power Inverter
Standard Inverter
* | * |
*R407C