Mitsubishi Electronics S, M Accessories, Conditions for specifications, How to read a model name

Models: M S P

1 48
Download 48 pages 55.78 Kb
Page 47
Image 47

Accessories

Model Name

Description

 

Compatible Models

MSDD-50SR-E

Distribution Pipe

 

 

PU(H)-P71/100/125/140 and PUHZ-RP/P71/100/125/140 Twin 50:50 use

MSDD-50WR-E

 

 

PU(H)-P200/250 and PUHZ-RP200/250 Twin 50:50 use

 

 

 

MSDD-50AR-E

Distribution Pipe (to connect 2 branch boxes): flare connection type

 

MXZ-8A140VA (PAC-AK30/50BC)

MSDD-50BR-E

Distribution Pipe (to connect 2 branch boxes): brazing type

 

MXZ-8A140VA (PAC-AK30/50BC)

MSDT-111R-E

 

 

 

PU(H)-P140/200/250 and PUHZ-RP/P140/200/250 Triple 33:33:33 use

SDT-112SA-E

Distribution Pipe

 

 

PU(H)-P140 and PUH-P200/250 Triple Use (25:25:50)

SDT-122SA-E

 

 

PUH-P200/250 Triple 20:40:40 use

 

 

 

MSDF-1111R-E

 

 

 

PU(H)-P200/250 and PUHZ-RP200/250 Quadruple 25:25:25:25 use

PAC-SG72RJ-E

Joint Pipe (unit φ6.35→pipe φ9.52)

 

 

 

PAC-SG73RJ-E

Joint Pipe (unit φ9.52→pipe φ12.7)

 

 

PUHZ-RP/P

PAC-SG74RJ-E

Joint Pipe (unit φ12.7→pipe φ15.88)

 

 

 

 

 

PAC-SG75RJ-E

Joint Pipe (unit φ15.88→pipe φ19.05)

 

 

PAC-SG76RJ-E

Joint Pipe (unit φ9.52→pipe φ15.88)

 

 

MXZ-8A140VA (PAC-AK30/50BC)

PAC-493PI

Joint Pipe (unit φ6.35→pipe φ9.52)

 

 

 

 

 

MAC-A454JP-E

Joint Pipe (unit φ9.52→pipe φ12.7)

 

 

MXZ-A14/18, MXZ-3A/4A, MXZ-8A140VA (PAC-AK30/50BC)

MAC-A455JP-E

Joint Pipe (unit φ12.7→pipe φ9.52)

 

 

MXZ-4A, MXZ-8A140VA (PAC-AK30/50BC)

MAC-A456JP-E

Joint Pipe (unit φ12.7→pipe φ15.88)

 

 

 

 

 

PAC-SG81DR-E

Filter Dryer for Liquid Pipe of φ6.35

 

 

PUHZ-RP35/50

PAC-SG82DR-E

Filter Dryer for Liquid Pipe of φ9.52

 

 

PUHZ-RP60/71/100/125/140, MXZ-8A140VA

PAC-SG85DR-E

Filter Dryer for Liquid Pipe of φ12.7

 

 

PUHZ-RP200/250

PAC-AK350CVR-E

Branch Box Outer Cover (for outdoor installation)

 

MXZ-8A140VA (PAC-AK30/50BC)

MAC-888SG

Air Outlet Guide

 

 

MXZ-2A

PAC-SF08SG-E

 

 

 

PU(H)-P (2 pieces required)

PAC-SG58SG-E

Air Outlet Guide (to change air blowing direction)

 

PUHZ-RP35/50: only 1 piece required

PAC-SG59SG-E

 

PUHZ-RP60/71: only 1 piece required

 

 

 

 

 

 

PUHZ-RP/P100/125/140, MXZ-8A140VA: 2 pieces required

 

 

 

 

PAC-SG56AG-E

 

 

 

PUHZ-RP35/50: only 1 piece required

PAC-SH63AG-E

Air Protect Guide (for cooling at -15

)

 

PUHZ-RP/P60/71: only 1 piece required

 

 

 

PUHZ-RP/P100/125/140

 

 

 

 

PAC-SG86AG-E

Air Protect Guide (for cooling at -15

, For Front & Rear side)

 

 

Conditions for specifications

Temperature conditions are based on JIS B8616

Cooling

Indoor

27˚C

DB, 19˚C

WB

Outdoor

35˚C

DB

 

 

 

Heating

Indoor

20˚C

DB

 

 

 

 

 

Outdoor

7˚C

DB, 6˚C

WB

 

 

 

 

 

 

Refrigerant piping length ;

5M

 

Total input are indicated based on the following voltages.

 

 

 

 

 

 

 

 

Indoor unit

 

Outdoor unit

50Hz

 

1ph / 230V

 

1ph. 230V / 3 ph. 400V

 

 

 

 

 

How to read a model name

1) M & S series

M M : M series S : S series

 

 

 

PUHZ-RP200/250

PAC-SG87AG-E

Air Protect Guide (for cooling at -15 , For Right & Left side)

 

PAC-SF37DS-E

Drain Socket

 

PU(H)-P

PAC-SG61DS-E

 

PUHZ-RP/P35/50/60/71/100/125/140, MXZ-8A140VA

 

 

S

"S"= Wall Mounted , "F"= Compact Floor Standing , "E"= Compact Ceiling Concealed , "L"= 4 Way Cassette , "U"= Outdoor unit

PAC-SG63DP-E

Centralized Drain Pan

PUHZ-RP35/50

 

PAC-SG64DP-E

PUHZ-RP/P60/71/100/125/140, MXZ-8A140VA, PU(H)-P

 

PAC-SG92DS-E

Centralized Drain Kit

PUHZ-RP200/250

 

PAC-SC32PTA

Program Timer

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SE41TS-E

Remote Sensor

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SE55RA-E

Remote On/Off Adapter

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SF40RM-E

Remote Operation Adapter

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SF80MA-E

M-NET Converter

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SK52ST

Control / Service Tool

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SK82SI-E

A-Control Sub Interface

All PU(H)-P and PUHZ-RP/P outdoor units

(A-control)

PAC-SC84PI-E

L-shape Connection Pipe

PKA-RP60/71FAL, PKA-RP50FAL2

 

PAC-SC86PI-E

PKA-RP100FAL for R410A use

 

 

 

MAC-1200FT

 

MCF(H)-GA35/50/60VB

 

MAC-1300FT

Air Cleaning Filter

MSC-GA20/25/35VB

 

MAC-1700FT

 

MS(H)-GA50/60/80VB, MSH-CB50VB

 

Z"Z"= Inverter Heat Pump , "H"= Fixed-Speed Heat Pump , "none"= Cooling Only

FSeries

AGeneration

25Rated cooling capacity (kW base)

V V= 50Hz / 230V / 1 Phase

A "A"= R410A with new A control , "B"= R410A with conventional control

2)P series

PP series

MAC-1700DF

Deodorizing Filter

MCF(H)-GA35/50/60VB

MAC-2300FT

Anti-Allergy Enzyme Filter

MSZ-GA60/71VA

MAC-415FT-E

MSZ-GA22/25/35/GB50, MSZ-CB22/25/35

 

U

"K"= Wall Mounted , "S"= Floor Standing , "L"= 4 Way Ceiling Cassette , "E"= Ceiling Concealed , "C"= Ceiling Suspended , "U"= Outdoor unit

MAC-305FT-E

Deodorizing Ceramic Filter

 

MSZ-FA25/35VA

MAC-093SS-E

Quick Clean Kit

 

MSZ-FA25/35VA, MSZ-GA22/25/35/GB50, MSZ-CB22/25/35

MAC-3003CF

Catechin Air Filter

 

MSZ-HA

PAC-SE80KF-E

 

 

PCA-RP50GA, PCH-P50GAH

PAC-SE81KF-E

High Efficiency Filter

 

PCA-RP60/71/100GA, PCH-P60/71/100GAH

PAC-SE82KF-E

 

 

PCA-RP125/140GA, PCH-P125/140GAH

PAC-1000FT

Air Filter

 

SEZ-KA

PAC-SG38KF-E

Oil Mist Filter Element (12 pieces)

 

PCA-RP HA

PAC-SG01KF-E

High Efficiency Filter Element

 

PLA-RP AA, PLH-P AAH

PAC-SG03TM-E

Multi-Functional Casement

 

PLA-RP AA, PLH-P AAH

PAC-SG04AS-E

Space Panel

 

PLA-RP AA, PLH-P AAH

PAC-SG06SP-E

Shutter Plate (2 pieces)

 

PLA-RP AA, PLH-P AAH

PAC-KE03DM-G

Drain Pump for Ceiling Concealed models

 

PEAD-RP EA/GA, PEHD-P EA

PAC-SE90DM-E

Drain Pump for Wall Mounted models

 

PKA-RP60/71/100FAL, PKH-P60/71/100FALH

PAC-SH20DM-E

 

 

PCA-RP50/60GA, PCH-P50/60GAH

PAC-SH21DM-E

Drain Pump for Ceiling Suspended models

 

PCA-RP71GA, PCH-P71GAH

PAC-SH22DM-E

 

 

PCA-RP100/125/140GA, PCH-P100/125/140GAH

PAC-SF28OF-E

Duct Flange for Fresh Air

 

PCA-RP HA

PAC-SF81KC-E

Decoration Covers (Front & Suspension Bracket Cover)

 

PCA-RP71HA

PAC-SF82KC-E

 

PCA-RP125HA

 

 

MAC-397IF-E

MA & Contact Terminal Interface

 

MSZ-FA/GA/GB, MFZ-KA, SEZ-KA/KC, SLZ-KA

MAC-399IF-E

M-NET Interface

 

 

 

MAC-821SC-E

Centralized On/Off Remote Controller (MAC-397IF-E required)

 

MSZ-FA/GA, MFZ-KA, SEZ-KA, SLZ-KA

PAR-21MAA-G

Wired Remote Controller (with Weekly Timer Function, MAC-397IF-E required)

 

MSZ-FA/GA, MFZ-KA

PAR-21MAAT-E

Wired Remote Controller Kit for Wall Mounted models

 

PKA-RP and PKH-P

PAR-SL99B-E

Wireless Remote Controller Kit for Ceiling Suspended models

 

PCA-RP and PCH-P

PAC-SG96HR-E

Power Supply Terminal Kit for new A-Control Indoor units (L/N/Earth)

 

PLA-RP, PKA-RP, PSA-RP, PCA-RP GA

PAC-SG97HR-E

Power Supply Terminal Kit for new A-Control Indoor units (L/N)

 

PEAD-RP EA/GA, PCA-RP HA

MAC-1200RC

Remote Controller Holder

 

MSZ-HA

H"H"=Heat Pump , "blank"= Cooling Only

Z "Z"=Inverter , "blank"= Fixed-Speed

RP "RP"= R410A & Cleaning Free Pipe Reuse, "P"=R410A

71Rated cooling capacity (kW base)

V"V"= 50Hz / 230V / 1 Phase , "Y"=50Hz / 400V / 3Phase

HGeneration

A "A"= A control

3)Multi System

MM series

X"X"=Multi System Outdoor unit (Heat Pump), "U"=Multi System Outdoor unit (Cooling Only)

Z "Z"= Inverter Heat Pump, "X"=Fixed-Speed Cooling Only Multi System

4Maximum number of connectable indoor units

A Generation

71 Rated cooling capacity (kW base)

V "V"= 50Hz / 230V / 1 Phase

A "A"= R410A with new A control , "B"= R410A with conventional control

91

92

Page 47
Image 47
Mitsubishi Electronics P Accessories, Conditions for specifications, How to read a model name, M series S S series