AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT
AIR FLOW velocity and direction can be selected as required.
■ To change the AIR FLOW velocity, press the FAN button.
AUTO AIR FLOW DIRECTION CONTROL OPERATION
When the AUTO mode is selected with the VANE button, the position of the horizontal vane is automatically set to corre-
|
|
| ˚C |
|
| CLOCK | AMPM |
| 12345 | ||
|
| ||
|
|
| AMPM |
ON/OFF | TOO | TOO | |
|
| WARM | COOL |
|
| FAN | STOP |
I FEEL |
|
| |
HEAT | AUTO |
|
|
|
| VANE | START |
DRY | COOL |
|
|
MODE |
| HR. | |
ECONO COOL |
| MIN. | |
|
| RESET CLOCK |
Each time the button is pressed, the fan speed is changed in sequence:
(Low) → (Med.) → (High) → (AUTO)
•Use the (High) notch to cool/heat the room more.
•If the operating sound of the air conditioner disturbs your sleep, use the (Low) notch.
■To change the AIR FLOW blowing direction vertically, press the VANE button.
Each time the button is pressed, the angle of the horizontal vane is changed in
sequence: 1 → 2 → 3 → 4 → 5 → (SWING) → (AUTO)
SWING OPERATION
Use the swing operation for the air flow to reach all corners of the room.
Recommended horizontal vane range |
| COOL | |
Use the | (AUTO) position usually. |
| |
| DRY | ||
1 |
| ||
Use position 1 or 2 in the COOL or DRY mode and use |
| ||
2 |
| ||
positions 3 to 5 in the HEAT mode when adjusting to | 3 | HEAT | |
4 | 5 | ||
|
|
|
your requirements.
spond to the operation mode for effective operation.
For the floor standing unit
(1) COOL, DRY |
| (2) HEAT |
|
|
|
|
|
|
|
• The air is blown out upwards. | • When the air flow temperature is | • When the air flow temperature | ||
|
| too low, the air is blown out up- | rises, the air is blown out hori- | |
|
| wards. | zontally. |
For the ceiling suspended unit
NOTE:
•In the cooling operation, when the air conditioner is operated with setting the horizontal vane to 4 or 5 for 1 hour, the AIR FLOW direction is automatically set to horizontal to prevent condensed water from dropping.
•Adjust the vertical AIR FLOW direction using the remote controller. If the horizontal vane is moved manually, it may cause trouble.
•In the heating operation, if the air flow temperature is too low or when defrosting is being done, the horizontal vane position is set to position 1.
■To change the horizontal direction of the AIR FLOW
For the floor standing unit | For the ceiling suspended unit |
• Change the direction of the vertical vane manually. | • Change the direction of the vertical vane manually. |
Adjust the vane before operation starts.
Since the horizontal vane moves automatically, your fingers may be caught.
(1) COOL, DRY |
| (2) HEAT |
|
|
• The air is blown out horizontally. | • When the air flow temperature | • When the air flow temperature | ||
|
| is too low, the air is blown out | rises, the air is blown out down- | |
|
| horizontally. | wards. |
NOTE:
•When the operation mode changes in “(AUTO)” mode, the horizontal vane is automatically changed to the position in each mode.