(9) To change the air flow direction not to blow directly onto your body.
To change the air | When to use this function? | COOL/DRY |
| HEAT | |
flow direction |
| ||||
|
|
| (for MSZ) | ||
|
|
|
| ||
Pressing and holding | Use this function if you don’t | The air conditioner starts the | The air conditioner starts heat- | ||
VANE CONTROL | want the air from the indoor | cooling or drying operation | ing operation approx. 3 minutes | ||
button for 2 seconds | unit to blow directly onto your | approx. 3 minutes after the | after the vane has moved to the | ||
body. | vane has moved to the hori- | horizontal position. | |||
or more causes | |||||
• Depending on the shape of | zontal position. | • | Sometimes the area | ||
the horizontal vane | |||||
the room,the air may blow | |||||
• When VANE CONTROL |
| around your feet may not | |||
to reverse and |
| ||||
directly onto your body. |
| ||||
| warm. To warn the area | ||||
move to horizontal | button is pressed again, |
| |||
|
| ||||
| the vane returns to the |
| around the feet, set the | ||
position. | • Press VANE CONTROL |
| |||
| horizontal vane to | ||||
| button again to return the |
| |||
| and the air conditioner |
| (AUTO) or the downward- | ||
| vane to the |
| |||
| starts the cooling or |
| blowing position. | ||
| position. |
| |||
| drying operation in | • | When VANE CONTROL | ||
Horizontal |
| ||||
| approx. 3 minutes. | ||||
|
| button is pressed again, | |||
position |
|
|
| ||
|
|
| the vane returns to the | ||
|
|
|
| ||
|
|
|
| ||
|
|
|
| and the air conditioner | |
|
|
|
| starts the heating operation | |
|
|
|
| in approx. 3 minutes. | |
|
|
|
|
|
NOTE:
•If you make the air flow not to blow directly onto your body by pressing VANE CONTROL button, the compressor stops for 3 minutes even during the operation of the air conditioner.
•The air conditioner operates with Very Low speed until the compressor turns on again.
(10)ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 3.6°F higher than that in COOL mode.
Also the horizontal vane swings in various cycle.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher than that in COOL mode, the air conditioner can keep comfort. As a result, energy can be saved.
ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL button is pressed or change to other operation mode.
(11) POWERFUL ( ) operation
The air conditioner automatically adjusts the fan speed and the set temperature, and operates the POWERFUL mode.The POWERFUL mode is automatically released 15 minutes after operation starts, and the operation mode returns to the mode prior to POWERFUL operation.
2.Vertical vane
(1)Vane motor drive
These models are equipped with a stepping motor for the vertical vane. The rotating direction, speed, and angle of the motor are controlled by pulse signals (approximate 12V) transmitted from microprocessor.
(2)The vertical vane angle and mode change as follows by pressing WIDE VANE button.
1![](/images/new-backgrounds/1014519/1451991xi5.webp)
2 ![](/images/new-backgrounds/1014519/1451991xi7.webp)
3![](/images/new-backgrounds/1014519/1451991xi9.webp)
4 ![](/images/new-backgrounds/1014519/1451991xi11.webp)
SWING ![](/images/new-backgrounds/1014519/1451991xi13.webp)
5![](/images/new-backgrounds/1014519/1451991xi15.webp)
6![](/images/new-backgrounds/1014519/1451991xi17.webp)
![](/images/new-backgrounds/1014519/1451991xi18.webp)
(3)Positioning
The vane is once pressed to the vane stopper to confirm the standard position and then set to the desired angle. Confirming of standard position is performed in the following cases.
(a)When OPERATE/STOP(ON/OFF) button is pressed (POWER ON/OFF).
(b)When SWING is started or finished.
(c)When the power supply turns ON.
(4)SWING MODE ( )
By selecting SWING mode with WIDE VANE button, the vertical vane swings horizontally. The remote controller displays “ .”
46