[RS-232C control flowchart]
| START |
|
| Sending out command |
|
No NAK returned |
| No response for |
Awaiting response | 1 second or longer | |
| from projector |
|
| NAK returned |
|
Command is sent successfully.
Command is executed successfully.
Checking execution of command (sending out check command)
OK
END
Command is sent successfully.
Command execution fails.
Check the following.
•Check that the function code is correct.
•Check that the data code is correct.
•Check that the projector is able to issue the return command.
NG | Check the projector’s operation using | |
the 00vST command. | ||
| ||
| Note: In the following cases, NAK is | |
| returned even when the projector is | |
| in normal condition. |
•Immediately after the power is turned on (about 20 seconds to 2 minutes)
•During input switching
•During auto positioning
•During password lock
Command sending fails.
Check the following.
•Check that the command begins with “00”.
•The projector is not supplied with AC power.
Check that AC power cord is connected.
Turn on the power. (Turn on the circuit breaker or main switch.)
•Not connected with the projector.
Check that the
Check the
[Method of checking state of projector]
Sending “00vST”
| 4 | ||
To normal operation |
|
| Checking response to “00vST” |
| |||
6 | 5 |
Projector error
Send out “00vER” to check error details.
Recover from error state.
Enter password.
Send out “00PASS****.”
Projector is functioning.
[Compatibility with the former models]
To use the
(For the recommended procedure to use the former command systems, see “Controlling the projector using a personal computer” for FL7000U.)
ITEM |
| Function |
| Data |
|
|
| ||
Character | ASCII |
| ||
|
|
| ||
|
|
|
|
|
Changing the | COMMAND | 43h 4Fh 4Dh 4Dh 41h 4Eh 44h | 0 | (Former command system), |
|
|
| 1 | (New command system) |
|
|
|
|
|
4