Lincoln Electric 575 manual Commander / K867 / LN-8 Connection Diagram

Models: 575

1 54
Download 54 pages 15.71 Kb
Page 41
Image 41

COMMANDER / K867 / LN-8 CONNECTION DIAGRAM

 

WARNING

Do not operate with panels open.

Keep guards in place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

before servicing.

Only qualified personnel should install,use

Do not touch electrically live parts.

or service this equipment.

CONNECTION DIAGRAM

F-6

Vantage 575

ELECTRODE

TO WORK

14PIN AMPHENOL

K867 UNIVERSAL

ADAPTER PLUG

SPARE 82 81 42 41

31

32

2

4

21 GND

}N.C.

31

32

2

4

21

GND

LN-8

WIRE

FEEDER

K196

INPUT CABLE

DIAGRAMS

TO WORK

ELECTRODE CABLE

TO WIRE FEED UNIT

CAUTION :

75

76

77

 

A

 

B

}

C

 

N.D.

 

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE

AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE

DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE

APPICATIONS. SEE OPERATING MANUAL.

N.B. USE VOLTMETER SWITCH TO SELECT DESIRED ELECTRODE POLARITY. POSITION THE SELECTOR SWITCH TO "WIRE WELDING CV".

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.D. SPLICE LEADS AND INSULATE.

7-2000

S23989

F-6

Page 41
Image 41
Lincoln Electric 575 manual Commander / K867 / LN-8 Connection Diagram