B-9

OPERATION

 

 

B-9

 

 

TABLE B.4 Vantage

 

 

 

 

 

Simultaneous Welding and Power Loads

 

 

 

 

 

 

 

 

 

 

 

Permissible

 

Permissible Auxiliary

 

 

Welding Output

Power - Watts

 

Current in Amperes

 

 

 

 

 

 

(Unity Power

 

 

 

 

 

 

 

 

 

 

 

 

Factor

@220 V ±10% *

@ 380 V ±10%

 

 

 

 

 

 

 

 

 

500A-40V

0

0

 

0

 

 

350A/34V

8100

40*

 

14 amp/phase

 

 

200A/30V

12000

50*

 

18.5 amp/phase

 

 

150A/26V

12000

50*

 

18.5 amp/phase

 

 

90A/24V

12000

50*

 

18.5 amp/phase

 

 

 

 

 

 

 

 

*Each receptacle is limited to 15 amps.

TABLE B.5 Vantage

Extension Cord Length Recommendations

Current

Voltage

Load

 

 

 

Maximum Allowable Cord Length in m (ft) for Conductor Size

 

 

(Amps)

Volts)

(Watts)

2.52mm (14AWG)

4.02mm

(12AWG)

6.02mm

(10AWG)

10.02mm

(8AWG)

16.02mm

(6AWG)

25.02mm

(4AWG)

15

230

3600

18

(60)

23

(75)

46

(150)

69

(225)

107

(350)

183

(600)

20

230

4800

 

 

18

(60)

30

(100)

53

(175)

84

(275)

1373

(450)

Conductor size is based on maximum 2.0% voltage drop

Vantage 575

Page 27
Image 27
Lincoln Electric 575 manual Table B.4 Vantage Simultaneous Welding and Power Loads