Moen 4200, 4641, 4643, 4340, 4330, 4350, 4220, 4400 Installation, Flushing, Lift Rod & Waste Assembly

Models: 4330 4643 4400 4641 4200 4340 4220 4350

1 4
Download 4 pages 48.67 Kb
Page 2
Image 2
Installation

Installation

Be sure lavatory or mounting surface is clean and dry. Place a bead of plumber's putty around the inside lip of the gasket. Lay gasket on deck and place faucet supplies and studs down through deck holes. Position faucet. Fasten faucet to deck, using clamp bars, spacers (if necessary), and mounting nuts on studs. Tighten. Engage tailpiece nuts on supplies to faucet nipples. Tighten nuts.

HOLD WITH

WRENCH

WARNING: Hold the faucet connection nipples with a wrench when tightening to prevent twisting and collapse of the tubing.

Flushing

TIGHTEN

 

IMPORTANT:

FAUCET

CONNECTION

NIPPLE

NUT

Pipe chips, sand, stones and other solids found in new and renovated plumbing can damage the sealing surface of the faucet cartridge and cause a leak. To avoid damage, DO NOT OPERATE VALVE until you have followed these instruc- tions:

a.Make sure all water supplies are OFF.

b.Remove handle parts, stop tube, retainer clip and cartridge (see "Disassembly" for detailed instructions).

c.At the supplies, slowly turn both hot and cold water on and thoroughly flush out the body and lines.

Lift Rod & Waste Assembly

(For model with grid strainer assembly follow steps 1-3 only)

1.

Thoroughly clean around drain opening in lavatory basin. Apply

 

1/4 inch bead of plumber's putty (not furnished) around the

 

underside of seat (as shown).

2.

Apply pipe joint compound or Teflon tape (not furnished) to top

 

threaded end of the drain body. Slip drain body up through the

 

drain opening and screw seat on the drain body.

3.

Position the drain body (with pivot rod opening extending rear-

 

ward) and tighten mounting nut until the drain body is snug. Wipe

 

excess plumber's putty from the seat area. Apply pipe joint

 

compound (not furnished) to top threaded end of tailpipe and

 

screw into the drain body. Tighten firmly by hand.

4.

Position the drain plug in either of the following ways:

 

A. VANDALPROOF - This design is to prevent unauthorized

 

removal of the drain plug. Unscrew the pivot nut and remove

 

the pivot rod. Inside the drain body position the pivot rod

 

through the drain plug hole as shown in the illustration below.

 

Screw the pivot nut back on the drain body. DO NOT

LIFT ROD

Flushing AND KNOB

DRAIN

 

 

BASIN

PLUG

 

 

 

VANDALPROOF

 

 

LIFT ROD

HOLE

 

 

 

 

 

STRAP

 

 

 

SCREW

SEAT

2-1/8"

PIPE

 

 

 

 

 

JOINT

 

 

 

COMPOUND

 

 

1-1/2"

OR TEFLON

 

PLUMBERS

TAPE

LIFT ROD

 

 

(NOT

STRAP

PUTTY

 

 

FURNISHED)

 

MAX 2-1/2"

 

 

 

 

 

MIN 1-1/2"

 

 

 

BOTTOM GASKET

Lift Rod & Waste Assembly FLAT WASHER

MOUNTING(For model with grid strainer assembly follow steps 1-3 only)

NUTSPRING

OVERTIGHTEN.

DRAIN BODY

CLIP

B. EASY REMOVAL - This design is for quick removal of drain

plug for cleaning. Just drop in the drain plug as shown in the

illustration below.

 

A. VANDALPROOF

B. EASY REMOVAL

 

 

POSITION FOR

 

 

EASY REMOVAL

PIVOT

VANDALPROOF

PIVOT

ROD

ROD

POSITION

 

 

8"

PIPE

 

 

 

 

JOINT

PIVOT NUT

 

COMPOUND

 

 

 

(NOT

PIVOT ROD

 

FURNISHED)

SEAT

 

TAILPIPE

PIVOT

 

ROD

 

 

 

 

1-1/4"

5.Hook up lift rod and knob, lift rod strap and spring clamp as shown.

6.With the drain plug in full open position, adjust lift rod and knob to clear faucet and tighten lift rod strap screw.

MT123A

Page 2
Image 2
Moen 4200 Installation, Flushing, Lift Rod & Waste Assembly, For model with grid strainer assembly follow steps 1-3 only