4517 BS ACSeries specs V3 24/6/05 10:52 AM Page 6
TECHNICAL SPECIFICATION SHEET FOR
BLUE SEAL ELECTRIC COMBI STEAMER
AC SERIES E10AC DD 10 x 1/1GN CAPACITY
Dimensions |
|
Width | 950mm |
Depth | 825mm |
Height | 1090mm |
Weight | 155kg |
Packed Dimensions |
|
Width | 1040mm |
Depth | 980mm |
Height | 1320mm |
Weight | 175kg |
Shelves |
|
1/1 GN | 10 |
Shelf Spacings | 70mm |
Installation requirements
(for precise installation instructions, please refer to the unit’s installation manual).
Power connection requirements
Multi pole circuit breaker and all pole disconnection isolator switch installed near the appliance.
Supply line voltage;
Special voltage options available on request.
Installation clearances
- rear 25mm
- right 500mm*
- left 50mm
*Clearance required on fixed installations for service accessibility.
If heat sources are located near the RH side of the AC combi, ensure that a minimum distance of 400mm is maintained.
Install in accordance with local bodyregulationsonlyonhorizontal surfaces and not against combustible walls.
Water connection requirements
-Cold water
-Flow pressure (2 to 6 bar)
-soft water connection*
-
-water supply R3/4
-R50 waste water connection
(*Water softener may be required. Please refer to installation manual for water treatment values.)
Australia
www.moffat.com.auNew Zealand
www.moffat.co.nzAustralia
Moffat Pty Limited
Victoria/Tasmania
740 Springvale Road Mulgrave, Victoria 3170 Telephone
New South Wales
Telephone
South Australia
Telephone
Queensland
Telephone
Western Australia
Telephone
Power Connection |
|
Total (kW) | 16 |
Convection power (kW) | 15 |
Rated Current (A) (400V) | 22 |
IPX5
Optional Extras
SC Core temperature probe
SPT10 Stainless steel stand with 10 x 1/1 GN shelves to suit 10AC DD
SST10 Removable rack complete with fitting frame alternative to side runners to suit 10AC DD
TLT10 Removable frame for oven and plate racks to suit 10AC DD
SGT10 Removable oven rack to suit 10AC DD
PRT10 Plate banquet rack to suit 10AC DD / 30 plates
CRT10 Trolley for removable oven rack with drip tray to suit 10AC DD
CPT10 Thermal cover for plate banqueting system to suit 10AC DD
KP004 Set of four legs for bench mounting
A = WATER CONNECTION R3/4 (SOFTENEDWATER)refertoinstallation manual for water treatment values.
B = WATER CONNECTION R3/4
C = DRAIN CONNECTION Ø50
D = ELECTRICAL CONNECTION ENTRY E = HIGH/LOW PRESSURE RELIEF VENT F = OVEN VENT Ø80
New Zealand
Moffat Limited
Christchurch
Telephone
Auckland
Telephone
In line with policy to continually develop and improve its products, Moffat Limited reserves the right to change specifications and design without notice.
Printed in China
©Copyright Moffat Ltd