3.0 INDICATORS AND SWITCHES
1 | 5 | 6 |
2
7
3
4
8
Figure 3 Smart Laser Sensor
1.On Target LED Lit whenever the sensor is receiving a reflected signal back from the target. As the frequency increases, it will be on solid unless the measured frequency is not stable. This is useful in setting up the unit.
2. | Laser On LED | Blinks when unit is first turned on. Remains |
|
| lit when the laser beam is on. |
3. | Auto/Gain LED | On solid whenever the unit is in the Auto |
|
| mode. It also blinks from 1 to 8 times to |
|
| indicate the current gain whenever the gain is |
|
| changed. |
4. | Power LED | (Dependent on the Power switch location) |
| On position: | GREEN when the batteries are charged. |
|
| Blinks AMBER when the batteries are low. |
| Charge position: | Blinks RED when fast charging for very |
|
| low batteries. |
|
| Blinks AMBER when slow charging. |
|
| Steady AMBER when the batteries are |
|
| fully charged. |
5. | Polarity switch | Selects either a positive or negative |
|
| output pulse. |
6. | Learn/Gain button |
|
| In Auto Mode: | Press and hold until the On Target LED |
|
| blinks regularly or is on solid. |
| In Manual Mode: | Press to change gain ranges. |
7.Sensitivity Adjust knob Turn fully counterclockwise to select Auto mode or manually adjust sensitivity threshold.
8. Power switch | Turns unit On or Off. When the unit is |
| switched to Off/Charge and a charger is |
| plugged into the unit, the batteries will |
| charge. |
4.0QUICK START GUIDE
4.1Slide Power switch (8) to “On”.
4.2Rotate Sensitivity Adjust knob (7) fully counterclockwise to the “Auto” position.
4.3Aim the laser dot perpendicular to the target - reflective tape, contrasting color or keyway.
4.4If the On Target LED (1) is not on, push and hold the Red Learn/Gain button (6) until the On Target LED (1) blinks regularly. Note that at higher RPMs the LED will be on solid.