LOG PLACEMENT

LOG PLACEMENT

Before you begin — This unit is supplied with four ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling the logs, wash your hands gently with soap and water to remove any traces of fibers.

WARNING

The positioning of the logs are critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite or rock wool to the heater. Only use the logs supplied with the unit.

Failure to position the parts in accordance with diagrams below or to use only parts specifically approved for this heater may result in property damage or personal injury.

Log #4

Log #2

Log

#1

Log

#3 DO NOT sprinkle volcanic rocks on the

Back

Pins

Front

Pins

Figure 12 - Installing

Logs to Grate

INSTALLING LOGS ON GRATE (See Figure 12)

1.Install back log (#1) on two pins located near the back of base. Check log position and stability.

2.Install center log (#2) on two pins located near the front of the base. Make sure the bottom of the log around the pin holes fully contacts the engine base.

3.Install front log (#3) in front of center log. Make sure bottom of log is resting on the grate. Do not rest log on burner.

4.Place back end of top center log (#4) on recessed area of back log (#1) and rest on pin on center log (#2).

 

 

 

DO NOT sprinkle volcanic rocks on the

CAUTION

 

logs or around the pilot. This may cause

 

sooting.

 

 

 

 

 

 

During initial operation of the new heater,

 

 

 

burning logs will give off a paper burning

 

 

 

smell and orange flames will be present.

 

 

 

Simply open the windows for a few hours

 

 

 

to vent the odor.

 

 

 

 