Monessen Hearth DFS32, MCFS36, DFS42 manual Product Specifications, Hardwood Surround Dimensions

Models: DFS36 DFS3224 MCFS36 DFS32 DFS42

1 4
Download 4 pages 40.24 Kb
Page 4
Image 4
SPECIFICATIONS

SPECIFICATIONS

Product Specifications

 

 

 

 

 

 

 

Manual

Millivolt

Thermostat

Hi/Lo

 

 

 

 

 

Width

Height

Depth

Control

Control

Control

Control

 

 

 

 

 

BTU (x1000)

BTU (x1000)

BTU (x1000)

BTU (x1000)

 

Opening

Radiant or

 

Model

Actual

Framing

Actual

Framing

Actual

Framing

NG

LP

NG

LP

NG

LP

NG

LP

 

Height

Circulating

Cert.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MCFS36

41"

41-1/4"

43"

43-1/2"

20-1/2"

21"

20-36

20-36

 

26"

Both

CSA

DFS32

37"

37-1/4"

37-1/2"

37-3/4"

16"

16"

18-28

18-28

18-28

20-28

18-28

20-28

18-28

21-28

20-1/2"

Both

CSA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFS3224

37"

37-1/4"

37-1/2"

37-3/4"

16"

16"

20-38

20-38

25-38

30-38

25-38

30-38

20-38

22-38

20-1/2"

Both

CSA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFS36

41"

41-1/4"

37-1/2"

37-3/4"

16"

16"

20-38

20-38

25-38

30-38

25-38

30-38

20-38

22-38

20-1/2"

Both

CSA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DFS42

47"

47-1/4"

37-1/2"

37-3/4"

16"

16"

20-38

20-38

25-38

30-38

25-38

30-38

20-38

22-38

20-1/2"

Both

CSA

Hardwood Surround Dimensions

 

 

32" Wall

32" Wall

36" Wall

36" Wall

 

*36" Wall

*36" Wall

 

 

Surround

Hearth

Surround

Hearth

 

Surround

Hearth

Width of mantel

 

50-1/2"

 

58"

54-3/8"

61-1/4"

 

58"

 

64-1/2"

Height w/o hearth

 

48"

 

5"

48-1/4"

5"

 

 

53"

 

5"

Depth

 

17-1/4"

 

21-3/8"

21-3/4"

25-1/2"

 

22"

 

25-1/2"

Opening width

 

38"

 

42"

 

42"

 

Opening height

 

35-7/8"

 

35-3/4"

 

40-3/4"

Width of mantel top

58"

 

62"

 

64-1/2"

Depth of mantel top

21-1/8"

 

25-1/2"

 

25-1/2"

 

 

 

 

 

 

 

 

 

 

 

 

*MCFS36

 

32" Corner

 

32" Corner

36" Corner

36" Corner

 

 

 

 

 

 

Surround

 

Hearth

 

Surround

Hearth

 

 

 

Width of mantel

62-3/8"

 

62-3/8"

 

63-3/8"

 

63-3/8"

 

 

Height w/o hearth

48-1/4"

 

5"

 

48-1/4"

 

5"

 

 

 

 

Distance from

 

 

 

 

 

 

 

 

 

 

 

 

corner to front

 

 

 

 

 

 

 

 

 

 

 

 

center of mantel

35-1/2"

 

 

37-1/2"

 

 

 

 

Distance from

 

 

 

 

 

 

 

 

 

 

 

 

corner to front

 

 

 

 

 

 

 

 

 

 

 

 

edge along wall

44-1/8"

 

 

47"

 

 

 

 

Opening width

38"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vent Free Fireplace System

Framing Dimensions

 

MCFS36

DFS32/24

DFS36

DFS42

A

41-1/4"

37-1/4"

41-1/4"

47-1/4"

B

43-1/2"

37-3/4"

37-3/4"

37-3/4"

C

30-1/2"

28-3/4"

32-1/2"

38-3/4"

D

15-1/4"

14-3/8"

16-5/8"

19-3/8"

E

71-1/2"

60-3/4"

65-1/4"

70-3/4"

F

35-3/4"

30-3/8"

32-5/8"

35-3/8"

G

21"

16"

16"

16"

H

50-1/2"

43"

46-1/4"

50"

C

A

Inside Chase Installation

C

G

A

Recessed Installation

 

H

D

 

 

G

 

F

B

 

G

 

 

C

A

 

A

 

E

Stud Location

 

 

Corner Installation

REGULATORY APPROVAL

The DFS and MCFS series has been tested and approved by CSA as an unvented room heater to the latest ANS Z21.11 requirements. Approved for installation in an aftermarket manufactured (mobile) home, where not pro- hibited by state or local codes. This unit complies with requirements to be classified as a zero clearance unit.

149 Cleveland Drive • Paris, Kentucky 40361

Warning:

It is recommended that the screen be used during operation of this log set. Always ensure the screen has adequate spaces to allow for passage of combustion air to the gas log set.

Correct installation of the ceramic fiber logs, proper location of the heater and periodic cleaning are necessary to avoid potential service problems with sooting.

Keep small chidren and animals away from the open flame of the gas log set at all times.

There may be a start-up odor associated with the heating of the logs. The odor should diminish in 2-3 hours of operation with the burner at its highest setting with the fan in the off position.

www.monessenhearth.com

To avoid personal injury or property damage, the product described by this brochure must be installed, operated and maintained in strict compliance with the instructions packaged with the product and all applicable building or fire codes. Contact local building or fire officials about restrictions and installation inspection requirements. All photographs and drawings on this brochure are for illustrative purposes only and are not intended for, nor should they be used as a substitute for the instructions packaged with the unit. Appearance and specifications of the product are subject to change without notice.

© 2004 Monessen Hearth Systems, Inc.

Sold by:

MADE IN U.S.A.

DFS/MCFS36-MHS3704

Rev. 07-04

Page 4
Image 4
Monessen Hearth MCFS36, DFS42, DFS3224, DFS36 manual Product Specifications, Hardwood Surround Dimensions