OPERATING INSTRUCTIONS
SAFETY INSTRUCTION FOR MANUAL CONTROL (SPK)
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING
If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A.BEFORE OPERATING smell all around the appli- ance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS:
•Do not attempt to light any appliance.
•Do not touch any electric switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
•If you cannot reach your gas supplier, call the fire department.
B.Use only your hand to push in, or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don't try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.
C.Do not use this appliance if any part of it has been under water. Immediately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
MANUAL CONTROL LIGHTING INSTRUCTIONS
1.STOP! Read the safety information label.
2.Make sure the manual shutoff valve is fully open.
3.Push in gas control knob slightly and turn clockwise to “OFF.”
NOTE: Knob cannot be turned to “OFF” unless knob is pushed in slightly.
4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information label. If you don’t smell gas, go to next step.
5.Find pilot — follow metal tube from gas control.
6.From “OFF” position, push in gas control knob slightly and turn counterclockwise to “PILOT.” Push in control knob for 5 seconds.
7.With the control knob pushed in, immediately light the pilot with a match. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
•If knob does not pop up when released, stop and immediately call your service technician or gas supplier.
•If the pilot will not stay lit after several tries, turn the gas control knob to off and call your service technician or gas supplier.
8.Turn gas control knob counterclockwise to “ON.”
Figure 145 -
Control Knob
Figure 146 - Manual Pilot
TO TURN OFF GAS TO HEATER
1. Push in gas control knob slightly and turn clockwise to OFF position. Do not force.
42 | 27D8520 |