Monte Carlo Fan Company 5ED56WAD Series Phillips Screwdriver, Tools Required, Step Ladder, Pliers

Models: 5ED56WAD Series

1 5
Download 5 pages 37.32 Kb
Page 2
Image 2
Phillips Screwdriver
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.

SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

To reduce the risk of fire, electric shock, or personal injury, mount to outlet box or supporting system acceptable for fan support. (Mounting must support at least 35 lbs.)

Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades. Attach the mounting bracket using only the hardware supplied with the outlet box.

To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

16. Note--For Outdoor Fans Only: Suitable for use in wet locations when installed in a GFCI protected branch circuit.

Phillips Screwdriver

TOOLS REQUIRED

Step Ladder

Wire Cutters

Pliers

1

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

2

Before installing this fan make sure the outlet box is properly installed to the house structure. To reduce the risk of fire, electric shock, or per sonal injury, mount to outlet box or supporting- system acceptable for fan support.

(Mounting must support at least 35 lbs.)

3

Use metal outlet box suitable for fan support (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a structural ceiling member ( a loose box will cause the fan to wobble). Use only the screws provided with the outlet box.

4

5

6

Remove keeper from pin. Pull pin out and replace keeper, save for later.

Loosen the 2 set screws and nuts till you can not feel them on inside of yoke.

Place canopy and then yoke cover over downrod as shown. Then thread the lead wires and safe- ty cable from fan through the downrod as shown.

Page 2
Image 2
Monte Carlo Fan Company 5ED56WAD Series Phillips Screwdriver, Tools Required, Step Ladder, Wire Cutters, Pliers