WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards (ANSI/NFPA 70- 1999), including fire-rated construction.

Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade.

WARNING – Risk of fire, electric shock, or personal injury, The fan in this box may be either directly supported from a structural framing mem- ber of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

9. Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating blades.

10 Attach the mounting bracket using only the hardware supplied with the outlet box.

11. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

12. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

13. NEVER place a switch where it can be reached from a tub or shower.

14. The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heating equip- ment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

15. Warning: Before attempting to replace the fuse make sure that the power is turned off to the fan. Replace only with 3 amp fuse.

16. Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

1

Phillips Screwdriver

Wire Cutters

Pliers

 

 

 

2

 

 

OUTLET BOX METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warning-Risk of fire, electric shock, or personal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

injury. The fan in this box may be either directly

 

 

Before you begin installing the fan, Switch power off

 

 

supported from a structural framing member of a

 

 

 

 

 

at Service panel and lock service disconnecting means

 

 

building and/or may be mounted to an outlet box

 

 

to prevent power from being switched on accidentally.

 

 

marked acceptable for fan support of of 31.8 kg (70

 

 

When the service disconnecting means cannot be

 

 

lbs) or less. Most outlet boxes commonly used for

 

 

locked, securely fasten a prominent warning device,

 

 

the support of lumminaires may not be acceptable

 

 

such as a tag, to the service panel.

 

 

for fan support and may need to be replaced.

 

 

 

 

 

 

 

Consult a qualified electrician if in doubt.

 

 

 

4

 

 

 

 

 

 

 

 

5

 

BUILDING STRUCTURE METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet box

 

 

Plate

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

 

 

Remove the 4 screws attaching the Mounting

 

 

Secure mounting plate directly to a joist from the

 

 

 

 

 

 

 

 

 

 

buliding structure via the two knock out holes on

 

 

 

neck the mounting plate. Retain the 4 screws

 

 

the outlet box. Use only the appropriate wood

 

 

 

for re-assembly.

 

 

screws and washers included with your fan.

 

 

 

 

 

Caution: Wood screws must go through into the

 

 

 

 

 

 

 

building joist.

 

 

 

 

 

 

Step Ladder

3

Remove Safety bar from mounting bracket by loosing screws, sliding bar to side, and lifting it off the 2 screws.

6

FAN BRACE AND BOX METHOD

Install the mounting Plate to approved fan brace and box combination use only the hard- ware provided with the fan brace and box.