Installation

SAFETY TIPS

WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,

OBSERVE THE FOLLOWING: READ AND SAVE THESE INSTRUCTIONS

1. Installation work and electrical wiring must be done by qualified person(s) in accordance with applicable codes and standards

2. (ANSI/NFPA 70-1999), including fire-rated construction.

3. Use this unit only in the manner intended by the manufacurer. If you have any questions contact the manufacturer.

After making the wire connections, the wires should be spread apart with the grounded conductor and the equipment-grounding con-

4. ductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box.

Before you begin installing the fan, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device,

5. such as a tag, to the service panel.

6. Be cautious! read all instructions and safety information before installing your new fan. Review the accompanying assembly diagrams.

7. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

Make sure the installation site you choose allows the fan blades to rotate without any obstructions. Allow a minimum clearance of 7

8. feet from the floor to the trailing edge of the blade.

WARNING – Risk of fire, electric shock, or personal injury. The fan in this box may be either directly supported from a structural fram- ing member of a building and/or may be mounted to an outlet box marked acceptable for fan support of 31.8 kg. (70 lbs.) or less. Most outlet boxes commonly used for the support of luminaires may not be acceptable for fan support and may need to be replaced.

9. Consult a qualified electrician if in doubt.

Do not bend blade holders during installation to motor, balancing or during cleaning. Do not insert foreign object between rotating

10. blades.

11. Attach the mounting bracket using only the hardware supplied with the outlet box.

12. To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed control device, or variable speed control.

13. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application.

14. NEVER place a switch where it can be reached from a tub or shower.

The combustion airflow needed for safe operation of fuel-burning equipment may be affected by this unit’s operation. Follow the heat- ing equipment manufacturer’s guideline safety standards such as those published by the National Fire Protection Association (NFPA),

15. and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.

Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

 

1

Phillips Screwdriver

Wire Cutters

Pliers

 

 

2

 

OUTLET BOX METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Before you begin installing the fan, Switch

 

 

 

 

Warning-Risk of

fire, electric shock, or personal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

injury. The fan in this box may be either directly sup-

 

 

 

power off at Service panel and lock service dis-

 

 

 

 

ported from a structural framing member of a build-

 

 

 

connecting means to prevent power from being

 

 

 

 

ing and/or may be mounted to an outlet box marked

 

 

 

switched on accidentally. When the service dis-

 

 

 

 

acceptable for fan support of 31.8 kg(70lbs) or less.

 

 

 

connecting means cannot be locked, securely

 

 

 

 

Most outlet boxes commonly used for the support of

 

 

 

fasten a prominent warning device, such as a

 

 

 

 

luminaires may not be acceptable for fan support and

 

 

 

 

 

 

 

may need to be replaced. Consult a qualified electri-

 

 

 

tag, to the service panel.

 

 

 

 

cian if in doubt.

 

 

 

 

 

 

 

 

4

 

 

 

 

5

 

BUILDING STRUCTURE METHOD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outlet box

 

 

Plate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Screws

 

 

 

 

 

 

 

 

 

Remove the 4 screws attaching the Mounting

 

 

Secure mounting plate directly to a joist from

 

 

 

 

 

 

 

 

 

 

neck to the mounting plate. Retain the 4

 

 

the buliding structure via the two knock out

 

 

 

 

 

holes on the outlet box. Use only the appropri-

 

 

 

screws for re-assembly.

 

 

ate wood screws and washers included with

 

 

 

 

 

 

 

 

your fan. Caution: Wood screws must go

 

 

 

 

 

 

 

 

through into the building joist.

 

 

 

 

 

 

 

 

Step Ladder

3

Remove Safety bar from mounting bracket by loosing screws, sliding bar to side, and lifting it off the 2 screws.

6

FAN BRACE AND BOX METHOD

Install the mounting Plate to approved fan brace and box combination use only the hard- ware provided with the fan brace and box.

Page 2
Image 2
Monte Carlo Fan Company 5ROR owner manual Installation, Such as a tag, to the service panel

5ROR specifications

The Monte Carlo Fan Company, a leading manufacturer of high-quality ceiling fans, offers a variety of elegant and functional designs tailored for different tastes and decor. Among its impressive range of products, the Monte Carlo 5ROR model stands out due to its combination of aesthetics, performance, and cutting-edge technology.

The Monte Carlo 5ROR is known for its sleek and modern design that integrates seamlessly into both contemporary and traditional settings. Available in several finishes, including brushed nickel and matte black, this fan adds a touch of sophistication to any room. It features five gracefully curved blades, which not only enhance its visual appeal but also contribute to its exceptional airflow efficiency.

One of the standout characteristics of the 5ROR is its powerful motor, which is engineered for optimal performance and energy efficiency. The fan operates quietly, providing a comfortable environment without distracting noise, making it perfect for bedrooms, living rooms, or home offices. The integrated motor ensures smooth and reliable operation, further enhancing the user experience.

Another impressive feature of the Monte Carlo 5ROR is its versatility. The fan is designed for use in both indoor and outdoor spaces, making it suitable for patios, verandas, or covered decks. Its wet-rated construction ensures durability and performance even in humid or exposed environments. The fan can be installed in various ceiling heights, thanks to the included downrod, giving users the flexibility to customize their airflow experience.

In terms of technology, the Monte Carlo 5ROR is compatible with popular smart home systems. With optional remote control and wall control features, users can easily adjust fan speed and lighting settings without the hassle of reaching for the pull chains. This modern convenience elevates the overall functionality and user-friendliness of the fan.

The energy efficiency of the 5ROR model is further complemented by its eco-friendly design. Built with high-quality materials, it consumes relatively low wattage while producing high airflow, allowing users to enjoy comfort without increasing their electricity bills significantly.

In summary, the Monte Carlo Fan Company 5ROR is a top-tier ceiling fan that combines striking design, advanced technology, efficient performance, and versatility. It is perfect for anyone seeking to enhance their living space with a stylish and functional ceiling fan that seamlessly integrates into their home environment.