Customer Service Center:

If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this Trouble Shooting Chart. If a problem cannot be remedied, or you are experiencing difficulty in installation, please call our Customer Service Center at the number printed on your parts list insert sheet.

Warning: Before servicing or cleaning unit, Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

1.If fan does not start:

2.If fan sounds noisy:

3.If fan wobbles:

4. If light does not work:

1.Check main and branch circuit fuses or circuit breakers.

2.Check line wire connections to fan and switch wire connections in switch housing.

3.Check to make sure the dip switches from the transmitter and receiver are set on the same frequency.

CAUTION: Make sure main power is turned off

1.Check to make sure all screws in motor housing are snug (not over tightened).

2.Check to make sure the screws which attach the fan blade holder to the motor are tight. 3.Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.

CAUTION: Make sure main power is turned off before entering switch housing. 4.Some fan motors are sensitive to signals from Solid State variable speed controls. DO NOT

USE a Solid State variable speed control.

5.Allow "break-in" period of 24 hours. Most noises associated with a new fan will disappear after this period.

1.Make sure that the ridge of the canopy engages the notch in the downrod ball. 2.Check that all blades are screwed firmly into blade holders.

3.Check that all blade holders are tightened securely to motor.

4.Make sure that canopy and mounting bracket are tightened securely to ceiling junction box and junction box is mounted firmly to ceiling joist.

5.Dynamic balancing involves ‘counter-weighting’. By using a small weight opposite to the point of wobble, you can in almost all cases eliminate the wobble. The procedure requires much trial and error, and a certain amount of patience to achieve the correct position of the counterweight. A) Determine which fan speed causes the most wobble. This will almost always be the highest speed. B) Turn the fan off. Select any one blade and place the balance clip half way between the blade tip and blade holder, on the rear edge of the blade. Caution: Be careful to stay clear of the blades when running. If the clip is not secure, injury may result from the clip fly- ing off. C) Turn the fan on. Observe if the wobble is better or worse. Turn the fan off and move the clip to the next blade. Do the same for all blades and note on which blade the clip improves the wobble the most. D) Place the clip on the blade which showed the most improvement and by trial and error move the clip in and out along the blade to find the position which most improves the wobble. E) Remove the clip and discard. Once the exact position is determined, place a weight on bottom of the metal blade holder on its centerline. Press the weight firmly to ensure it is firmly attached to the blade holder. Add more weight as needed to balance.

1.Check wire from fan to make sure it is connected to hot wire from house. 2.Check for loose or disconnected wires in fan switch housing.

3.Check for loose or disconnected wires in light kit. 4.Check for faulty light bulbs.

CAUTION: Make sure main power is turned off before entering switch housing.