73342 rev1 13/3/07 15:02 Page 6
FILTERS
Replacing the HEPA exhaust filter E
The HEPA exhaust filter should be replaced every 6 months.
•Replacement filters can be purchased from our replacement parts helpline.
1Remove the front grille E to access the HEPA filter.
Safety cut-out
If the cleaner overheats a motor protection thermostat will automatically switch the motor off. If this happens, switch the cleaner off, unplug from the power supply and leave the cleaner to cool for at least 60 minutes. Check the airways for blockages, replace the dust bag, clean the
Changing the belt
If the brush bar stops rotating it is likely that the drive belt has snapped (usually because the brush has been stalled). A spare belt is supplied. Replacement belts can also be obtained from Morphy Richards.
Removing the floor nozzle cover FG
1Disconnect the cleaner from the mains supply.
2Press the handle release pedal and place the cleaner face down, in the flat position on a soft surface (eg carpet).
3Use a
remove the four screws indicated F.
4Turn the cleaner over.
5While pressing the handle release pedal lift the rear of the top cover, unhook from the front
then completely remove the cover G.
| Replacing the belt HI | E |
6 | Lift off the belt cover Î. |
|
7 | Gently pull the right hand side |
|
| (belt side) of the floor nozzle |
|
| outwards and at the same time |
|
| lift the brush bar Ï out of its |
|
| location H. |
|
8 | If the belt has broken, ensure all |
|
| pieces are removed. Clean the |
|
| motor shaft Ì. |
|
9 | Check the brush bar end caps. | F |
| ||
| Ó |
|
10 | Fit the left hand end cap into the |
|
| floor nozzle. |
|
11 | Fit the right hand end cap onto |
|
| the brush bar. |
|
12 | Place one end of the new belt |
|
| over the motor shaft Ì and the |
|
| other around the pulley end of |
|
| the brush Ï. | G |
13 Locate the left hand side of the brush bar first, then while pulling the right hand side of the nozzle gently outwards and stretching the belt, lower the right hand side of the brush into its location.
14 Rotate the brush by hand to |
|
|
|
|
ensure it is correctly and | H | Î |
|
|
|
| |||
securely located. |
|
|
|
|
15 | IMPORTANT: |
|
|
| cover. |
|
|
16 | Replace the top cover, hooking it |
|
|
| in at the front first and by |
|
|
| pressing the handle release | Ï |
|
| pedal to allow the rear to |
|
|
| correctly locate J. | I | Ì |
|
| ||
17 | Turn the cleaner face down and |
| |
|
| ||
|
|
| |
| screws, do not overtighten. |
|
|
18 | Return the cleaner to its correct |
|
|
| working position before re- |
| Ó |
| testing. |
| |
|
|
| |
|
| J |
|
6 |
| UK Helpline 0870 060 2604 Replacement Parts 0870 167 6635 Ireland Helpline 1800 409119 | 6 |