3.Select Install the software automatically (Recommended), and then click Next to proceed.
4.The next window cautions you that this software has not passed Windows logo testing. This is a standard warning, and Moxa has thoroughly tested the driver for safe Windows operation. Please click Continue Anyways to proceed.
5.A window will appear showing the model name and indicating that Windows has completed the driver installation. Click Finish.
5. Installing the Port Driver
1.The Found New Hardware Wizard will automatically open to install the driver for the new serial port. Select No, not this time, then click Next.
2.Select Install the software automatically (Recommended), and then click Next to proceed.
3.The next window cautions you that this software has not passed Windows logo testing. This is a standard warning, and Moxa has thoroughly tested the driver for safe Windows operation. Please click Continue Anyways to proceed.
4.After all files have been copied to the system, the Completing the Found New Hardware Wizard window will open to indicate that the wizard has finished installing the new COM port. Please click Finish.
6.Installing the Linux Driver for the UPort 1100 Series.
1.Execute the following commands from the Linux prompt: #mount /dev/cdrom /mnt/cdrom
#cd / #mkdir moxa #cd moxa
#cp /mnt/cdrom/<driver
directory>/driv_linux2.6_uport1p_vx.x_build_xx.tgz #tar xvfz driv_linux2.6_uport1p_vx.x_build_xx.tgz
2.#cd mxu11x0/driver #make clean; make install
3.#modprobe mxu11x0
7. Serial Port Pin Assignments
The UPort 1100 series uses male DB9 connectors. Pin assignments are shown in the following diagram:
Male DB9 |
|
|
|
|
|
|
| ||
|
|
|
|
| Pin |
|
|
| |
1 | 2 | 3 | 4 5 |
|
|
| |||
|
|
|
|
| 1 | DCD (in) | |||
|
|
|
|
| 2 | RxD (in) | TxD+(B) | ||
|
|
|
|
| |||||
|
|
|
|
| 3 | TxD (out) | RxD+(B) | Data+(B) | |
6 | 7 | 8 | 9 | 4 | DTR (out) | ||||
5 | GND | GND | GND | ||||||
|
|
|
|
| |||||
|
|
|
|
| 6 | DSR (in) | |||
|
|
|
|
| 7 | RTS (out) | |||
|
|
|
|
| 8 | CTS (in) |
The UPort 1130/1150/1150I comes with a DB9 to terminal block converter, with pin assignments as shown below:
Terminal Block
Pin | |||
| |||
1 | TxD+(B) | ||
2 | |||
3 | RxD+(B) | Data+(B) | |
4 | |||
5 | GND | GND |
Note that the converter maps pin 1 on the DB9 connector to pin 2 on the terminal block, and pin 2 on the DB9 connector to pin 1 on the terminal block.
8. Certification
This product complies with Chinese RoHS (Restriction of Hazardous Substances) regulations for Electronic Information Products.
Copyright ♥ 2008
Moxa Inc.
All rights reserved.
Reproduction without permission is prohibited.
Tel:
Fax:
— 4 — | — 5 — | — 6 — |