Moyer Diebel 401-HTM2 PLUS Electrical Schematics, 0510653, SCHEMATIC 401+ SERIES HTN

Models: 401-HTM2 PLUS 401-LTM2 PLUS 401-HTNM2 PLUS

1 51
Download 51 pages 42.08 Kb
Page 47
Image 47
CUSTOMER TO SUPPLY RATED

ELECTRICAL SCHEMATICS

CUSTOMER TO SUPPLY RATED

VOLTAGE/PHASE/Hz, AS SPECIFIED

PER ORDER, TO DISCONNECT SWITCH.

ALL POWER SUPPLIED TO EACH CONNECTION

POINT MUST COMPLY WITH ALL LOCAL

ELECTRICAL CODES.

TO CUSTOMER RECEPTACLE

115V 60Hz

BLK WHT

GND

1

MSW

34

ON

1

 

 

 

 

4

 

5

NO

OFF

CAM 8

 

NC

6

NONO

CAM 1

NC 7 NC

1CR

12

 

 

8

 

 

 

 

 

 

 

CLT

 

 

 

 

 

8

 

8

8

 

 

 

 

 

 

 

TM

 

 

 

 

 

 

 

 

WASH/

BLU

START CW

 

 

 

 

13

/RINSE

 

 

9

9 L SRC S 12

NO

 

 

1

 

 

CAM 3

 

 

 

 

 

NO

 

 

 

RED

START CCW

8

 

NC

14

DRAIN

CAM 2

 

2

 

 

NC

M

 

 

 

 

 

 

 

15

 

 

15

BLK

MAIN

 

 

 

 

 

 

3

 

 

 

NO

 

 

2

WHT

 

 

 

19

F V

 

TP

 

 

CAM 5

 

 

4

8NC

2

2

20

NO

CAM 4

8NC

16

NO

(IF USED)

5

GRN

 

 

DP

2

 

 

 

20 D V

2

GND

 

GND

 

2

 

PSDR 16

34

21

CAM 7

8NC

DM

2

17

17

NO

(IF USED)

22

CAM 6

8NC

RM

2

1

 

DSS

 

1

50

2

 

 

1CR

BLK

BLACK

CLT

CYCLE ON LIGHT

 

PSS

PRIME SWITCH SANITIZER

BLU

BLUE

DM

DETERGENT MOTOR

ICR

RELAY

 

CAM 1

HOMING

DP

DRAIN PUMP

(IF USED)

DSS

REED SWITCH

 

CAM 2

PUMP MOTOR

RL

RELAY

 

RM

RINSE MOTOR

(IF USED)

CAM 3

PUMP MOTOR REVERSING

DV

DRAIN VALVE

 

SRC

CURRENT OPERATED START RELAY COIL

CAM 4

DRAIN

FV

FILL VALVE

 

SM

SANITIZER MOTOR

 

CAM 5

FILL

GND

GROUND

 

TM

TIMER MOTOR

 

CAM 6

RINSE

GRN

GREEN

 

TP

THERMAL PROTECTOR

 

CAM 7

DETERGENT

HTLS

HIGH LIMIT THERMOSTAT

WHT

WHITE

 

CAM 8

CYCLE

MSW

MAIN SWITCH ON/FILL OFF/DRAIN

WHTR

WATER HEATER

 

 

 

PSDR

PRIME SWITCH DETERGENT, RINSE

WTS

WATER THERMOSTAT

A

 

RELEASED TO

SKH

AUG

 

PRODUCTION

 

01/03

REV

ECN

DESCRIPTION

BY

DATE

CH

 

 

 

 

TOLERANCE

 

HOLE DIMENSIONS

ISSUED

SCHEMATIC 401+ SERIES HTN

DECIMAL

A

 

F

 

 

ANGLE

B

 

G

 

DR.

 

 

SCALE 1:1

C

 

 

 

DRAWING NO.

 

 

 

CH.

 

 

 

 

 

 

FORMING:DIMENSIONS ARE FROM

E

 

J

 

RTG.

 

0510653

BRAKELINE TO BRAKELINE

D

 

H

 

 

 

UNLESS OTHERWISE NOTED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 13 — Electrical Diagram, 401-HTN PLUS

41

Page 47
Image 47
Moyer Diebel 401-HTM2 PLUS, 401-HTNM2 PLUS, 401-LTM2 PLUS Electrical Schematics, 0510653, SCHEMATIC 401+ SERIES HTN