GENERAL
A new feature of the series MH12 heaters is a
18 ½ hours on No. 2011 P.O.L. Cylinder – Refillable 37 hours on No. 2020 P.O.L. Cylinder – Refillable
Above figures are calculated on the assumption that the heater is turned “Full On” at all times. Because it will not be necessary in many cases to have the heater turned “Full On” at all times, you can count on considerably longer burning times for each cylinder. Cylinders are available in most sporting goods stores, camping centers and propane outlets.
ASSEMBLY INSTRUCTIONS FOR MODEL MH12
DIRECTLY CONNECTED TO CYLINDER
1.Make sure
2.Inspect the condition of the flat rubber washer in the regulator for dirt or damage. (Do this each time the cylinder is attached.)
3.Carefully screw the heater onto the cylinder filled with propane. (Make sure no open flame is in the area.)
4.Check its connection by brushing on soapy water. If bubbles occur, tighten connections and again brush on soapy water.
CONNECTIONS MUST BE GAS TIGHT. SEE LIGHTING INSTRUCTIONS BEFORE LIGHTING.
CAUTION: THIS APPLIANCE CONSUMES AIR.
When used indoors (such as in tents, tent trailers, fishing huts, cabins, houses, house trailers) ALWAYS BE SURE TO PROPERLY VENTILATE THESE ENCLOSURES in which the heater is being used, by providing a fresh air opening of at least 12 square inches. When used indoors (such as in the enclosures listed above), mount the appliance on a horizontal surface at least 24” above the floor and make sure the heater is NOT within 50 feet of flammable vapors and clear of all combustible materials by the following measurements:
Top: | 20 ½ “ | 52.2 cm | DO NOT LEAVE YOUR APPLIANCE UNATTENDED. |
Sides: | 9” | 22.9 cm | |
Front: | 28” | 71.2 cm | DO NOT OPERATE YOUR APPLIANCE WHEN SLEEPING. |
Rear: | 8” | 20.3 cm |
LIGHTING INSTRUCTIONS:
1.After complying with the Assembly Instructions, turn regulator valve knob
2.Apply lighted match to bottom of mesh screen.
3.Push in valve button to ignite, then slowly release after 20 seconds.
4.Repeat Step #2 and #3 if heater does not stay lit.
5.To turn heater “Off” –
Models MH12, MH12T – Turn regulator knob clockwise to “Off” position. Turn off gas supply at cylinder.
REGULATING:
Heater output can be adjusted by turning the valve knob to “Low”, “Med.” Or “Hi” position.
WARRANTY:
Camp Heaters No. MH12 series are covered by a