Fiber Driver

EM316E1/EM316T1

EM316E1 Jumper Settings for E1 75Application :

1)Install jumpers between JP3 pins 3 and 4,

2

4

 

JP3

 

3

2)Install jumpers between JP4 pins 1 and 2, JP5 pins 1 and 2

2

2

JP4

 

1

1

JP5

3)Set all switches on S1 to ON.

(BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing mode

S1

O

N

1 2 3 4 5

LINE LENGTH BIT0 LINE LENGTH BIT1 LINE LENGTH BIT2 RECEIVE CODE TYPE TRANSMIT CODE TYPE