Fiber Driver
EM316E1/EM316T1
EM316T1 Jumper Settings for T1 100Ω Application :
1.) Install jumpers between JP3 pins 1 and 2,
2 | 4 |
| JP3 |
| 3 |
2.) No jumpers on JP4 and JP5 open, (all pins are open, no headers, not used)
2
JP4
2
JP5
1 1
3)Set RECEIVED CODE and TRANSMIT CODE on S1 to ON. (Choose B8ZS as encoder & decoder testing mode)
S1
O
N
1 2 3 4 5
LINE LENGTH BIT0 LINE LENGTH BIT1 LINE LENGTH BIT2 RECEIVE CODE TYPE TRANSMIT CODE TYPE
4)Set LINE LENGTH (BIT0, BIT1, BIT2) according to the table below to match copper cable length (default settings: BIT2=ON, BIT1=OFF, BIT0=OFF,
|
| BIT2 | BIT1 | BIT0 | Copper cable length |
|
|
| ON | OFF | OFF | 0 - 133 feet |
|
|
| OFF | ON | ON | 133 - 266 feet |
|
|
| OFF | ON | OFF | 266 - 399 feet |
|
|
| OFF | OFF | ON | 399 - 533 feet |
|
|
| OFF | OFF | OFF | 533 - 655 feet |
|
|
|
|
|
|
|
|
P/N: |
|