When programming this register, you must enter all Flag (Bit) values. The
flags are preset to the following: Flag 1 (Bit 3) Device 4 Barge-in Mask 0 (off)
Flag 2 (Bit 2) Device 3 Barge-in Mask 0 (off)
Flag 3 (Bit 1) Device 2 Barge-in Mask 0 (off)
Flag 4 (Bit 0) Device 1 Barge-in Mask 0 (off)
Register 8 must also be set to a positive number to activate barge-in.
REGISTER 08 - Barge-In Time
This register contains the amount of time that a telephone receiver must be held
off-hook to "barge-in" on a call. The range of this register is 0 (off) to 15 with a 2
second multiplier for each digit. Factory preset to 0 (off).
REGISTER 09 - Security Programming Time Window
This register contains the number of minutes that the ACP will accept the
programming code once power has been applied to the unit. The range of this
register is 0 to 15.
Factory preset to 0 (allows programming at all times).
REGISTER 10 - Seizure Time
This register contains the maximum number of seconds the ACP will hold the
phone line, during a multiple polling sequence after a device has been
disconnected. This register ranges from 10 to 99. Factory preset to 25 (no ring
back is provided to caller during this time).
(Note: ACP-9 utilizes Registers 11-15 plus 26-29. ACP-5 uses Registers 11-
15, and ACP-3 utilizes Registers only 11-13 for Device Codes.
REGISTER 11 - Security Access Code for Device Port 1
Contains the security access code for device port 1. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 11.
REGISTER 12 - Security Access Code for Device Port 2
Contains the security access code for device port 2. This register holds up to 7
digits ranging from 0 to 9, * and #. Factory preset to 22.
REGISTER 13 - Security Access Code for Device Port 3
Contains the security access code for device port 3. This register holds up to
digits ranging from 0 to 9 ' and #. Factory preset to 33
REGISTER 14 - Security Access Code for Device Port 4
Contains the security access code for device port 4. This register holds up to 7
digits ranging from 0 to 9, " and #. Factory preset to 44.