Chapter 3 – AT Commands, S-Registers, and Results Codes

 

 

Command:

%DPn Read Line Probe Data

Values:

n = 0 or 1

Default:

0

 

Description:

%DP0 Do not read and store line probe information from DSP during handshake.

 

%DP1 Read and store line probe information from DSP during handshake.

Command:

>DTn

DTMF Detection

Values:

n = 0 or 1

Default:

0

 

Description:

>DT0 The modem will not detect DTMF tones.

 

>DT1 The modem will detect and report DTMF tones when it is off-hook.

Command:

En Echo Command Mode Characters

Values:

n = 0 or 1

Default:

1

 

Description:

E0 Do not echo keyboard input to the terminal.

 

E1 Do echo keyboard input to the terminal.

Command:

&En V.42 Error Correction Modes

Values:

n = 0, 1, or 2

Default:

1

 

Description:

&E0 V.42 non-error correction mode (V.42 disabled).

 

&E1 V.42 auto-reliable mode.

 

&E2 V.42 reliable mode (V.42 enabled).

Command:

&En

Modem-Initiated Flow Control

Values:

n = 3, 4, or 5

Defaults:

4

 

Description:

&E3 Flow control disabled.

 

&E4 CTS/RTS hardware flow control.

 

&E5 XON/XOFF software flow control.

Command:

&En

XON/XOFF Pass-Through

Values:

n = 6 or 7

Defaults:

6

 

Description:

&E6 Respond to and discard XON/XOFF characters when &E5 is selected.

 

&E7 Respond to and pass through XON/XOFF characters when &E5 is selected.

Command:

&En Hewlett Packard ENQ/ACK Pacing

Values:

n = 8 or 9

Default:

8

 

Description:

&E8 Ignore ENQ/ACK pacing characters.

 

&E9 Respond to ENQ/ACK pacing characters.

Command:

&En Non-Error Correction Mode Flow Control

Values:

n = 10 or 11

Default:

10

 

Description:

&E10 Disable non-error correction mode flow control.

 

&E11 Enable non-error correction mode flow control.

Command:

&En Pacing (Computer-Initiated Flow Control)

Values:

n = 12 or 13

Default:

13

 

Description:

&E12 Pacing disabled.

 

&E13 Pacing enabled.

Command:

&En

Data Compression

Values:

n = 14 or 15

Default:

15

 

Description:

&E14 Data compression disabled.

 

&E15 Data compression enabled.

Multi-Tech Systems, Inc. MT2834ZDX User's Guide

10

Page 10
Image 10
Multi-Tech Systems MT2834ZDX manual DPn Read Line Probe Data, DTn Dtmf Detection, En Echo Command Mode Characters