Troubleshooting
None of the LEDs light when the MTA128ST/NT is on
When you turn on the MTA128ST/NT, the LED indicators on the front panel should flash briefly as the TA runs a
•Make sure the MTA128ST/NT’s power switch is on, especially if you normally turn on the TA by turning on a power strip.
•If the power supply is plugged into a power strip, make sure the power strip is plugged in and its power switch is on.
•Make sure the power supply module is firmly connected to the MTA128ST/NT and to the wall outlet or power strip.
•If the power strip is on and the MTA128ST/NT is switched on, try moving the TA’s power supply to another outlet on the power strip.
•Test that the outlet is live by plugging a lamp into it.
•The MTA128ST/NT or power supply may be defective. If you have another
Caution: Do not under any circumstances replace the power supply module with one designed for another product, as it may damage the MTA128ST/NT and void your warranty.
The MTA128ST/NT does not respond to commands
•Make sure the MTA128ST/NT is plugged in and turned on. (See None of the LEDs Light When the MTA128ST/NT Is On.)
•Try resetting your MTA128ST/NT by turning it off and on.
•Make sure you are issuing the MTA128ST/NT commands from the data communications software, either automatically, or manually in terminal mode. (You cannot send commands to the MTA128ST/NT from the DOS prompt.)
•Make sure you are in terminal mode in your data communications program. Then type AT and press ENTER. If you get an OK response, your connections are good and the problem likely is in your phonebook entry or session settings.
•If you don’t get an OK, the problem may still be in the communications software. Make sure you have done whatever is necessary in your software to make a port connection. Not all communications pro- grams connect automatically to the COM port. Some connect when the software loads and remain connected until the program ends. Others, like MultiExpress Terminal, can disconnect without ending the program (make sure the Connect icon looks plugged in). MultiExpress Terminal also allows multiple terminals to be open, but only one can access the MTA128ST/NT at a time. If MultiExpress Terminal reports that it cannot make a connection, yet the MTA128ST/NT’s TR indicator is on, click on the Window menu to see if more than one terminal is open. The MTA128ST/NT’s TR indicator shows that the software has made a connection with the TA through the COM port.open, but only one can access the MTA128ST/NT at a time. If MultiExpress Terminal reports that it cannot make a connection, yet the MTA128ST/NT’s TR indicator is on, click on the Window menu to see if more than one terminal is open. The MTA128ST/NT’s TR indicator shows that the software has made a connection with the TA through the COM port.
•Your communications software settings may not match the physical port the MTA128ST/NT is connected to. The serial cable may be plugged into the wrong
•If the MTA128ST/NT is on, the cable is plugged into the correct port, the communications software is configured correctly, and you still don’t get an OK, the fault may be in the serial cable. Make sure it is firmly connected at both ends.
MTA128ST/NT | 36 |