C-30HDN PUMP — OPERATION AND PARTS MANUAL — REV. #11 (03/29/12) — PAGE 25

C-30HDN PUMP — INSPECTION

Gasoline Check
1. Remove the gasoline cap located on top of fuel tank.
2. Handle Fuel in a safety container. If the container does not
have a spout use a funnel.
3. Visually inspect to see if fuel level is low. If fuel is low,
replenish with unleaded fuel. When refueling, be sure to use
a strainer for filtration. DO NOT top-off fuel. Wipe up any
spilled fuel.
4. Pay attention to the fuel tank capacity when replenishing fuel.
Refer to the fuel tank capacity listed in Table 5.
Lubrication Box
The model C-30HDN model features a fully enclosed

lubrication box,

which utilizes the

"SPLASH"

method of
lubrication.
Before using your new pump, 7 gallons of SAE 30 motor oil must
be added directly into the lubrication box. Visually inspect the oil
in the lubrication box by making sure the oil is at the correct
operating level as indicated by the dip stick (Figure 16).
Also reference the oil level decal (Figure 17) adjacent to the
lubrication box.
Figure 16. Lubrication Box Dipstick
Figure 17. Lubrication Box Oil Caution Decal
NOTE

Gasoline

is extremely flammable, and its
vapors can cause an explosion if ignited.
DO NOT start the engine near spilled fuel
or combustible fluids. DO NOT fill the fuel
tank while the engine is running or hot.
DO NOT overfill tank, since spilled fuel
could ignite if it comes into contact with hot engine parts or
sparks from the ignition system. Store fuel in approved
containers, in well-ventilated areas and away from sparks and
flames. NEVER use fuel as a cleaning agent.
DO NOT smoke while refueling, motor fuels are highly
flammable and can be dangerous if mishandled.
WARNING - Explosive Fuel Make sure the pump is on a secure
level surface when checking the oil
level inside the lubrication box.

CAUTION -

Checking Lubrication Oil Levels

The oil level must be

checked daily

to ensure adequate oil
level and oil cleaniness.