500kW Containerized Diesel Generator Set

Cooling System

Exhaust Manifold Type

Dry

Radiator Design

Standard horizontal discharge

 

 

Coolant Capacity - Engine

11.6 gal. (44 L)

 

 

Coolant Capacity - Engine and Radiator

42 gal. (159 L)

Water Pump Design/Type

Belt Driven, Centrifugal

Coolant Flow

79 gal/min (299 L)

 

 

Heat Rejection to Coolant

11535 BTU/min (202.7 kW)

Fan Horsepower

23 hp (17 kW)

Thermostat

188.6 °F (87 °C)

 

 

Fuel System

 

 

 

 

 

 

Recommended Fuel

ASTM-D975-No.1 or No. 2-D

 

 

 

 

Fuel Pump Maximum Lift

 

6.0 ft. (1.8 m)

Filter Micron Size - 98% Efficiency

 

2

 

Total Fuel Flow

186.1 gal./hr. (704.5 L/Hr.)

 

 

 

 

Fuel Consumption

 

 

 

 

 

 

Diesel Fuel @ % of Load

gal/hr

 

L/hr

25%

10.1

 

38.2

50%

18.1

 

68.5

 

 

 

 

75%

26.8

 

101.4

100%

37.7

 

142.7

 

 

 

 

Lubrication System

 

 

 

 

 

 

 

 

Type

Full Pressure System

 

 

Oil Filters

2 Spin-on, Full Flow

Oil Pan Capacity

12.2

gal. (46.0

L)

 

 

 

 

Oil Capacity with Filters

14.3

gal. (54.0

L)

 

 

Oil Pressure at Rated Speed

47 - 57 psi (324 - 393 kPa)

 

 

 

 

Exhaust System

Exhaust Temperature at Rated kW

980 oF (527 oC)

(Dry Exhaust)

 

Exhaust Flow at Rated kW

4080 cfm (115.5 m3/min)

Silencer Type

Critical

Maximum Allowable Backpressure

41.1 in/wc (10.2 kPa)

Exhaust Outlet Size at hook-up

5.0 in. (127 mm)

 

 

Inteligen Digital Genset Controller

Digital Controller Features

Large graphic back-lit LCD display 128x64 pixel resolution

Automatic and manual starting and stopping

Phase sequence supervision

Automatic shutdown/alarm function

Input frequency 50-60 Hz

Parameters adjustable via PC or iG keyboard

Predefined and user definable configurations available. One configuration includes set of inputs/outputs and parameters

Adjustable parameters for each configuration

6 LED indicators

Push buttons for simple control

4 programmable outputs (out of 20 functions selection)

4 binary configuration inputs

Lamp test during start up

Real time clock

Sealed membrane panel to IP65

180 x 113 mm front panel mounted case

Speed measurement from magnetic pickup

Oil pressure, Coolant temperature, Battery voltage and Fuel level measurements

Running Hour Meter

All Generator metering, kVAr, kW, V1-V3, Hz, I1-I3, kWh, kVAh

Generator under/over voltage alarm/shutdown

Generator under/over frequency alarm/shutdown

Over Current alarm/shutdown

Warm up and cooling functions

Pre-lubrication function with timers

Adjustable crank attempts

Data logging

Remote communications (RS232/Modbus)

EGC500DD Rev 2

Page 3
Image 3
Multiquip EGC500DD warranty Cooling System, Fuel System, Lubrication System, Exhaust System, Digital Controller Features