GA-6HZR — OPERATING INSTRUCTIONS

Before Starting

1.Be sure to disconnect the electrical load and switch the main circuit breaker to the “OFF” position prior to starting the engine.

2.Never start the engine with the main circuit breaker “ON”.

3.Check the lubricating oil level prior to starting the engine. Make sure the generator is level. The oil level must be maintained between two notches on the dipstick.

4.When there is not enough lubricating oil, fill the crankcase with high grade motor oil. Use a high quality detergent oil classified SC, SD or SE. (See Table 3 on page 13)

CAUTION:

NEVER start the engine when the oil level is below the lower mark on the dipstick.

Check the fuel level on the fuel gauge. When fuel is low, fill the fuel tank with clean fresh unleaded automotive gasoline.

If gasoline spillage occurs, completely wipe up the spilled gasoline.

Starting

1.Place the idle control switch in the “ON” (up) position.

2.Close the choke. Adjust the opening of the choke valve according to operating conditions. When the engine is warm or the air temperature is high, close the choke valve halfway or open it all the way.

3.Confirm that the main circuit breaker on the generator control box is “OFF”.

4.Set the operation switch to the “ON” position and grasp the starting rope and slowly pull it out. The resistance becomes hardest at a certain position, corresponding to the compression point. Rewind the rope a little from that point and pull out sharply.

5.If the engine fails to start, repeat the procedure.

CAUTION:

DO NOT pull the starter rope all the way to the end.

DO NOT release the starter rope after pulling. Allow it to rewind as soon as possible.

Warm up

1.When the engine starts, open the choke slowly.

2.Run the engine at low speed for 3 minutes without load until the engine warms up.

3.Turn the idle control switch to the "OFF" (down) position and check the voltage by referring to the voltmeter on the control box.

CAUTION:

DO NOT change the engine speed control lever which has been set at the factory prior to shipping.

1.Check the generator for abnormal noise and smells.Then connect the load to the receptacles of the generator.

2.Switch the main circuit breaker to the “ON” position and turn the idle control switch to the “ON” (down) position for normal (load) engine operation.

Operation

Check the voltage by referring to the voltmeter on the control box. When the voltmeter indicates 120 volts, 120 volts from the 120V receptacles and 240 volts from the 240V receptacle can be obtained at the same time. Refer to Figure 1, Controls and Indicators, item 4 on page 10.

Stopping the Engine

CAUTION:

NEVER stop the engine suddenly while running at high speeds.

1.Remove the load from the generator. Place the circuit breaker in the “OFF” position. Refer to Figure 1, item 5 on page 10. Run the engine (no-load) with the idle control switch set to the ON position for three to five minutes, then stop the engine.

2.Turn the START/STOP switch to the “STOP” position.

3.Never stop the engine suddenly while running at high speed.

4.Close the fuel cock.

PAGE 16 — GA-6HZR A.C. GENERATOR— OPERATION AND MANUAL — REV. #3 (03/30/11)

Page 16
Image 16
Multiquip GA6HZR manual GA-6HZR Operating Instructions

GA6HZR specifications

The Multiquip GA6HZR is a versatile and robust diesel generator, designed to deliver reliable power in a variety of settings including construction sites, events, and emergency backup scenarios. It is particularly noted for its innovative engineering and high-performance capabilities, making it a preferred choice among professionals in need of dependable power solutions.

One of the key features of the GA6HZR is its powerful engine, which typically consists of a four-cylinder diesel engine that provides substantial output while maintaining fuel efficiency. This engine is engineered to produce an output of up to 6,000 watts, making it suitable for a variety of equipment and applications. The generator is also equipped with an automatic voltage regulator (AVR), ensuring a steady and consistent voltage supply, which is critical for sensitive electronic equipment.

Safety and durability are paramount in the design of the GA6HZR. The generator features a heavy-duty, weather-resistant enclosure that protects it from the elements, thereby enhancing its longevity. Additionally, it is designed to minimize noise levels, adhering to regulations for sound pollution without compromising performance. The built-in fuel tank has a large capacity, enabling extended run times between refueling, which is particularly advantageous for long-term operations.

Another significant characteristic of the Multiquip GA6HZR is its portability. The generator comes with rugged wheels and handles, making it easy to transport across job sites or between different locations. This level of mobility ensures that users can quickly deploy power wherever it is needed most.

In terms of technology, the GA6HZR incorporates advanced features such as hour meters and control panels that provide real-time information about the generator’s performance and operational status. This enhances user convenience and allows for proactive maintenance planning, ensuring that the generator operates efficiently for a longer duration.

Overall, the Multiquip GA6HZR stands out due to its powerful performance, robust construction, and user-friendly design. It is an excellent solution for those seeking a reliable, high-capacity generator that can handle demanding power needs across various applications. Whether for professional or emergency use, the GA6HZR remains a trusted choice in the generator market.